Energy tanks have gained popularity inside the robotics and control communities over the last years, since they represent a formidable tool to enforce passivity (and, thus, input/output stability) of a controlled robot, possibly interacting with uncertain environments. One weak point of passification strategies based on energy tanks concerns, however, their initialization. Indeed, a too large initial energy can cause practical unstable behaviors, while a too low initial energy level can prevent the correct execution of the task. This shortcoming becomes even more relevant in presence of uncertainties in the robot model and/or environment, since it may be hard to predict in advance the correct (safe) amount of initial tank energy for a successful task execution. In this paper we then propose a new strategy for addressing this issue. The recent notion of closed-loop state sensitivity is exploited to derive precise bounds (tubes) on the tank energy behavior by assuming parametric uncertainty in the robot model. These tubes are then exploited in a novel nonlinear optimization problem aiming at finding both the best trajectory and the minimal initial tank energy that allow executing a positioning task for any value of the uncertain parameters in a given range. The approach is finally validated via a statistical analysis in simulation and experiments on real robot hardware.

Optimal Energy Tank Initialization for Minimum Sensitivity to Model Uncertainties / Pupa, A., Giordano, P.R., Secchi, C.. - (2023), pp. 8192-8199. (2023 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2023 usa 2023) [10.1109/IROS55552.2023.10341568].

Optimal Energy Tank Initialization for Minimum Sensitivity to Model Uncertainties

Pupa A.;Secchi C.
2023

Abstract

Energy tanks have gained popularity inside the robotics and control communities over the last years, since they represent a formidable tool to enforce passivity (and, thus, input/output stability) of a controlled robot, possibly interacting with uncertain environments. One weak point of passification strategies based on energy tanks concerns, however, their initialization. Indeed, a too large initial energy can cause practical unstable behaviors, while a too low initial energy level can prevent the correct execution of the task. This shortcoming becomes even more relevant in presence of uncertainties in the robot model and/or environment, since it may be hard to predict in advance the correct (safe) amount of initial tank energy for a successful task execution. In this paper we then propose a new strategy for addressing this issue. The recent notion of closed-loop state sensitivity is exploited to derive precise bounds (tubes) on the tank energy behavior by assuming parametric uncertainty in the robot model. These tubes are then exploited in a novel nonlinear optimization problem aiming at finding both the best trajectory and the minimal initial tank energy that allow executing a positioning task for any value of the uncertain parameters in a given range. The approach is finally validated via a statistical analysis in simulation and experiments on real robot hardware.
2023
Inglese
2023 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2023
usa
2023
IEEE International Conference on Intelligent Robots and Systems
8192
8199
9781665491907
Institute of Electrical and Electronics Engineers Inc.
345 E 47TH ST, NEW YORK, NY 10017 USA
Pupa, A.; Giordano, P. R.; Secchi, C.
Atti di CONVEGNO::Relazione in Atti di Convegno
273
3
Optimal Energy Tank Initialization for Minimum Sensitivity to Model Uncertainties / Pupa, A., Giordano, P.R., Secchi, C.. - (2023), pp. 8192-8199. (2023 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2023 usa 2023) [10.1109/IROS55552.2023.10341568].
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1368050
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
  • OpenAlex ND
social impact