Background: A core tenet of total knee arthroplasty (TKA) is that achieving more natural kinematics will lead to superior patient outcomes. Yet this relationship has not been proven for large representative cohorts of TKA patients because accurately measuring 3-dimensional TKA kinematics is time-consuming and expensive. But advanced imaging systems and machine learning–enhanced analysis software will soon make it practical to measure knee kinematics preoperatively and postoperatively in the clinic using radiographic methods. The purpose of this study was to assess the reported relationships between TKA kinematics and outcomes and distill those findings into a proposal for a clinically practical protocol for a clinical kinematic exam. Methods: This study reviewed the recent literature relating TKA kinematics to patient outcomes. There were 10 studies that reported statistical associations between TKA kinematics and patient outcome scores utilizing a range of functional activities. We stratified these activities by the complexity of the radiographic examination to create a proposed examination protocol, and we generated a list of requirements and characteristics for a practical TKA clinical kinematic examination. Results: Given considerations for a clinically practical kinematic exam, including equipment, time and other resources, we propose 3 exam levels. With basic radiographs, we suggest studying single-leg stance in extension, lunge or squat, and kneeling. For fluoroscopic systems with X-ray pulses up to 20 ms, we propose chair-rise or stair ascent to provide additional dynamic information. For fluoroscopic systems with X-ray pulses of less than 10 ms, we propose rapid open-chain knee flexion-extension to simulate the highly dynamic swing phase of gait. Conclusions: It is our hope that this proposed examination protocol spurs discussion and debate so that there can be a consensus approach to clinical examination of knee and TKA kinematics when the rapidly advancing hardware and software capabilities are in place to do so.

Total Knee Arthroplasty Kinematics Predict Patient-Reported Outcome Measures: Implications for Clinical Kinematic Examinations / Banks, S. A.; Catani, F.; Deckard, E. R.; Mahoney, O. M.; Matsuda, S.; Meneghini, R. M.; Victor, J. M. K.. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - 39:8(2024), pp. S224-S229. [10.1016/j.arth.2024.02.014]

Total Knee Arthroplasty Kinematics Predict Patient-Reported Outcome Measures: Implications for Clinical Kinematic Examinations

Catani F.;
2024

Abstract

Background: A core tenet of total knee arthroplasty (TKA) is that achieving more natural kinematics will lead to superior patient outcomes. Yet this relationship has not been proven for large representative cohorts of TKA patients because accurately measuring 3-dimensional TKA kinematics is time-consuming and expensive. But advanced imaging systems and machine learning–enhanced analysis software will soon make it practical to measure knee kinematics preoperatively and postoperatively in the clinic using radiographic methods. The purpose of this study was to assess the reported relationships between TKA kinematics and outcomes and distill those findings into a proposal for a clinically practical protocol for a clinical kinematic exam. Methods: This study reviewed the recent literature relating TKA kinematics to patient outcomes. There were 10 studies that reported statistical associations between TKA kinematics and patient outcome scores utilizing a range of functional activities. We stratified these activities by the complexity of the radiographic examination to create a proposed examination protocol, and we generated a list of requirements and characteristics for a practical TKA clinical kinematic examination. Results: Given considerations for a clinically practical kinematic exam, including equipment, time and other resources, we propose 3 exam levels. With basic radiographs, we suggest studying single-leg stance in extension, lunge or squat, and kneeling. For fluoroscopic systems with X-ray pulses up to 20 ms, we propose chair-rise or stair ascent to provide additional dynamic information. For fluoroscopic systems with X-ray pulses of less than 10 ms, we propose rapid open-chain knee flexion-extension to simulate the highly dynamic swing phase of gait. Conclusions: It is our hope that this proposed examination protocol spurs discussion and debate so that there can be a consensus approach to clinical examination of knee and TKA kinematics when the rapidly advancing hardware and software capabilities are in place to do so.
2024
39
8
S224
S229
Total Knee Arthroplasty Kinematics Predict Patient-Reported Outcome Measures: Implications for Clinical Kinematic Examinations / Banks, S. A.; Catani, F.; Deckard, E. R.; Mahoney, O. M.; Matsuda, S.; Meneghini, R. M.; Victor, J. M. K.. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - 39:8(2024), pp. S224-S229. [10.1016/j.arth.2024.02.014]
Banks, S. A.; Catani, F.; Deckard, E. R.; Mahoney, O. M.; Matsuda, S.; Meneghini, R. M.; Victor, J. M. K.
File in questo prodotto:
File Dimensione Formato  
PIIS088354032400113X.pdf

Accesso riservato

Tipologia: VOR - Versione pubblicata dall'editore
Dimensione 345.58 kB
Formato Adobe PDF
345.58 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1366533
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact