This paper reports about the design of a bio-inspired compliant wrist, whose mobility (i.e. ulnar-radial deviation and flexion-extension) has been realized by employing two pairs of contact-aided Cross-Axis Flexural Pivots (CAFPs), actuated via remotely-placed servo-motors and tendon transmissions. The human wrist behaves differently when deflecting in clockwise or anticlockwise direction, both in terms of maximum angular deflection and passive stiffness. The device proposed hereafter aims at mimicking such natural asymmetry, while withstanding unexpected external loads. In order to fulfill these requirements, two contacts are included: (i) a pure rolling contact (named passive contact), achieved via a cam mechanism guiding the CAFP deflection and ensuring the wrist resistance to compressive loads; (ii) a purposely shaped contact pair (named active contact), acting on one beam of the CAFP so as to increase its stiffness. The design procedures and tools specifically developed for the wrist optimization are described. In the first step, a CAFP shape optimization is performed, followed by the synthesis of the active contact pair. In the second step, the centrodes are computed and then used to generate the passive contact profiles. At last, the third step focuses on the definition of the tendons routing. To prove the validity of the numerical models, a physical prototype of the wrist is produced and tested. Direct comparisons between simulations and experiments confirm the efficacy of the proposed design method.
Design of a bio-inspired contact-aided compliant wrist / Bilancia, P.; Baggetta, M.; Berselli, G.; Bruzzone, L.; Fanghella, P.. - In: ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING. - ISSN 0736-5845. - 67:(2021), pp. 102028-102028. [10.1016/j.rcim.2020.102028]
Design of a bio-inspired contact-aided compliant wrist
Bilancia P.
;Berselli G.;
2021
Abstract
This paper reports about the design of a bio-inspired compliant wrist, whose mobility (i.e. ulnar-radial deviation and flexion-extension) has been realized by employing two pairs of contact-aided Cross-Axis Flexural Pivots (CAFPs), actuated via remotely-placed servo-motors and tendon transmissions. The human wrist behaves differently when deflecting in clockwise or anticlockwise direction, both in terms of maximum angular deflection and passive stiffness. The device proposed hereafter aims at mimicking such natural asymmetry, while withstanding unexpected external loads. In order to fulfill these requirements, two contacts are included: (i) a pure rolling contact (named passive contact), achieved via a cam mechanism guiding the CAFP deflection and ensuring the wrist resistance to compressive loads; (ii) a purposely shaped contact pair (named active contact), acting on one beam of the CAFP so as to increase its stiffness. The design procedures and tools specifically developed for the wrist optimization are described. In the first step, a CAFP shape optimization is performed, followed by the synthesis of the active contact pair. In the second step, the centrodes are computed and then used to generate the passive contact profiles. At last, the third step focuses on the definition of the tendons routing. To prove the validity of the numerical models, a physical prototype of the wrist is produced and tested. Direct comparisons between simulations and experiments confirm the efficacy of the proposed design method.File | Dimensione | Formato | |
---|---|---|---|
RCIM_PolsoCafp.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
6.67 MB
Formato
Adobe PDF
|
6.67 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris