The aim of this study was to investigate the migration pattern of the Lubinus SP II prosthesis stem. Migration at the stem-cement and at the bone-cement interface was assessed. Twenty-five patients were studied by radiostereometry during a period of 2 years. The migration of the head, of 2 points on the collar, of the stem tip, and also of the cement restrictor, was measured. The collar and the head were found stable at 2 years' follow-up, whereas an anterior migration occurred at the stem tip (median, 0.3 mm; 25th percentile, 0.04 mm; 75th percentile, 1.27 mm). Virtually no subsidence or axial rotation of the stems was observed. An anterior migration of the restrictor marker was also observed, compatible with a rigid sagittal plane rotation of the stem and of the cement mantle about the collar. Therefore, stem tip migration occurred at the bone-cement interface. Key words: total hip arthroplasty, anatomic stem, radiostereometry, subsidence, bone-cement interface.

Migration of cemented stem and restrictor after total hip arthroplasty: A radiostereometry study of 25 patients with Lubinus SP II stem / Catani, Fabio; A., Ensini; A., Leardini; L., Bragonzoni; S., Toksvig Larsen; S., Giannini. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - ELETTRONICO. - 20:2(2005), pp. 244-249. [10.1016/j.arth.2004.09.039]

Migration of cemented stem and restrictor after total hip arthroplasty: A radiostereometry study of 25 patients with Lubinus SP II stem

CATANI, Fabio;
2005

Abstract

The aim of this study was to investigate the migration pattern of the Lubinus SP II prosthesis stem. Migration at the stem-cement and at the bone-cement interface was assessed. Twenty-five patients were studied by radiostereometry during a period of 2 years. The migration of the head, of 2 points on the collar, of the stem tip, and also of the cement restrictor, was measured. The collar and the head were found stable at 2 years' follow-up, whereas an anterior migration occurred at the stem tip (median, 0.3 mm; 25th percentile, 0.04 mm; 75th percentile, 1.27 mm). Virtually no subsidence or axial rotation of the stems was observed. An anterior migration of the restrictor marker was also observed, compatible with a rigid sagittal plane rotation of the stem and of the cement mantle about the collar. Therefore, stem tip migration occurred at the bone-cement interface. Key words: total hip arthroplasty, anatomic stem, radiostereometry, subsidence, bone-cement interface.
2005
20
2
244
249
Migration of cemented stem and restrictor after total hip arthroplasty: A radiostereometry study of 25 patients with Lubinus SP II stem / Catani, Fabio; A., Ensini; A., Leardini; L., Bragonzoni; S., Toksvig Larsen; S., Giannini. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - ELETTRONICO. - 20:2(2005), pp. 244-249. [10.1016/j.arth.2004.09.039]
Catani, Fabio; A., Ensini; A., Leardini; L., Bragonzoni; S., Toksvig Larsen; S., Giannini
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/739504
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact