Objective: To establish the accuracy of bioelectrical impedance analysis (BIA) for the assessment of total and appendicular body composition in peritoneal dialysis (PD) patients. Design: Cross-sectional study. Setting: University Nephrology Clinic. Subjects: In all, 20 PD patients and 77 healthy controls matched for gender, age and body mass index. Methods: Whole-body fat-free mass (FFM) and appendicular lean tissue mass (LTM) were measured by dual-energy X-ray absorptiometry. Resistance ( R) of arms, trunk and legs was measured by eight-polar BIA at frequencies of 5, 50, 250 and 500 kHz. Whole-body resistance was calculated as the sum of R of arms, trunk and legs. The resistance index ( RI) was calculated as the ratio between squared height and whole-body or segmental R. Results: RI at 500 kHz was the best predictor of FFM, LTMarm and LTMleg in both PD patients and controls. Equations developed on controls overestimated FFM and LTMarm and underestimated LTMleg when applied to PD patients. Specific equations were thus developed for PD patients. Using these equations, the percent root mean-squared errors of the estimate for PD patients vs controls were 5 vs 6% for FFM, 8 vs 8% for LTMarm and 7 vs 8% for LTMleg. Conclusion: Eight-polar BIA offers accurate estimates of total and appendicular body composition in PD patients, provided that population-specific equations are used.

Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients / G., Medici; Mussi, Chiara; Al, Fantuzzi; Malavolti, Marcella; Albertazzi, Alberto; G., Bedogni. - In: EUROPEAN JOURNAL OF CLINICAL NUTRITION. - ISSN 0954-3007. - STAMPA. - 59:(2005), pp. 932-937. [10.1038/sj.ejcn.1602165]

Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients

MUSSI, Chiara;MALAVOLTI, Marcella;ALBERTAZZI, Alberto;
2005

Abstract

Objective: To establish the accuracy of bioelectrical impedance analysis (BIA) for the assessment of total and appendicular body composition in peritoneal dialysis (PD) patients. Design: Cross-sectional study. Setting: University Nephrology Clinic. Subjects: In all, 20 PD patients and 77 healthy controls matched for gender, age and body mass index. Methods: Whole-body fat-free mass (FFM) and appendicular lean tissue mass (LTM) were measured by dual-energy X-ray absorptiometry. Resistance ( R) of arms, trunk and legs was measured by eight-polar BIA at frequencies of 5, 50, 250 and 500 kHz. Whole-body resistance was calculated as the sum of R of arms, trunk and legs. The resistance index ( RI) was calculated as the ratio between squared height and whole-body or segmental R. Results: RI at 500 kHz was the best predictor of FFM, LTMarm and LTMleg in both PD patients and controls. Equations developed on controls overestimated FFM and LTMarm and underestimated LTMleg when applied to PD patients. Specific equations were thus developed for PD patients. Using these equations, the percent root mean-squared errors of the estimate for PD patients vs controls were 5 vs 6% for FFM, 8 vs 8% for LTMarm and 7 vs 8% for LTMleg. Conclusion: Eight-polar BIA offers accurate estimates of total and appendicular body composition in PD patients, provided that population-specific equations are used.
2005
59
932
937
Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients / G., Medici; Mussi, Chiara; Al, Fantuzzi; Malavolti, Marcella; Albertazzi, Alberto; G., Bedogni. - In: EUROPEAN JOURNAL OF CLINICAL NUTRITION. - ISSN 0954-3007. - STAMPA. - 59:(2005), pp. 932-937. [10.1038/sj.ejcn.1602165]
G., Medici; Mussi, Chiara; Al, Fantuzzi; Malavolti, Marcella; Albertazzi, Alberto; G., Bedogni
File in questo prodotto:
File Dimensione Formato  
medici 2005.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 152.47 kB
Formato Unknown
152.47 kB Unknown   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/611697
Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 51
social impact