Three different electrodes were tested for use as nonspecific amperometric sensors for blind analysis on real matrices, namely different fruit juices from different fruits or different brands. The first two electrodes were traditional Pt and Au electrodes, while the third one was modified with poly(3,4-ethylenedioxythiophene) conducting polymer. The sensors were tested separately, tested coupled to each other, and also tested together. The responses of the electrode system(s) were first screened via PCA and then their discriminant capabilities were quantified in terms of the sensitivities and specificities of their corresponding PLS-DA multivariate classification models. Particular attention was paid to analyzing the evolution of the response over subsequent potential sweeps. The modified electrode demonstrated the most discriminating ability, and it was the only system capable of satisfactorily performing the most complex task attempted during the analysis: discriminating between juices from the same fruit but from different brands. Moreover, the electrode cleaning procedure required between two subsequent potential sweeps was much simpler for the modified electrode than for the others. This electrode system was therefore shown to be a good candidate for use as an informative element in an electronic tongue applied to the analysis of other food matrices.
Development of an electronic tongue based on a PEDOT-modified voltammetric sensor / V., Martina; K., Ionescu; Pigani, Laura; Terzi, Fabio; Ulrici, Alessandro; Zanardi, Chiara; Seeber, Renato. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - STAMPA. - 387:6(2007), pp. 2101-2110. [10.1007/s00216-006-1102-1]
Development of an electronic tongue based on a PEDOT-modified voltammetric sensor
PIGANI, Laura;TERZI, Fabio;ULRICI, Alessandro;ZANARDI, Chiara;SEEBER, Renato
2007
Abstract
Three different electrodes were tested for use as nonspecific amperometric sensors for blind analysis on real matrices, namely different fruit juices from different fruits or different brands. The first two electrodes were traditional Pt and Au electrodes, while the third one was modified with poly(3,4-ethylenedioxythiophene) conducting polymer. The sensors were tested separately, tested coupled to each other, and also tested together. The responses of the electrode system(s) were first screened via PCA and then their discriminant capabilities were quantified in terms of the sensitivities and specificities of their corresponding PLS-DA multivariate classification models. Particular attention was paid to analyzing the evolution of the response over subsequent potential sweeps. The modified electrode demonstrated the most discriminating ability, and it was the only system capable of satisfactorily performing the most complex task attempted during the analysis: discriminating between juices from the same fruit but from different brands. Moreover, the electrode cleaning procedure required between two subsequent potential sweeps was much simpler for the modified electrode than for the others. This electrode system was therefore shown to be a good candidate for use as an informative element in an electronic tongue applied to the analysis of other food matrices.File | Dimensione | Formato | |
---|---|---|---|
ABC_2007_387_2101–2110.pdf
Solo gestori archivio
Tipologia:
Versione pubblicata dall'editore
Dimensione
467.38 kB
Formato
Adobe PDF
|
467.38 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris