In this paper, ordinary FMEA (Failure Mode and Effects Analysis) was applied during the design phase of an electric motor control system for vehicle HVAC (HeatingNentilation/Air Conditioning). The analysis of the field data from the second year forces to review FMEA. The corrective actions, planned on the basis of the sole failure mode, as usual in FMEA, proved to be inadequate and Failure Analysis was performed to understand the failure mechanism of the indicted component and integrate. New proper corrective actions were devised and successfully implemented.
Failure Analysis-assisted FMEA / Cassanelli, Giulia; G., Mura; Fantini, Fausto; M., Vanzi; B., Plano. - In: MICROELECTRONICS RELIABILITY. - ISSN 0026-2714. - STAMPA. - 46:9-11(2006), pp. 1795-1799. [10.1016/j.microrel.2006.07.072]
Failure Analysis-assisted FMEA
CASSANELLI, Giulia;FANTINI, Fausto;
2006
Abstract
In this paper, ordinary FMEA (Failure Mode and Effects Analysis) was applied during the design phase of an electric motor control system for vehicle HVAC (HeatingNentilation/Air Conditioning). The analysis of the field data from the second year forces to review FMEA. The corrective actions, planned on the basis of the sole failure mode, as usual in FMEA, proved to be inadequate and Failure Analysis was performed to understand the failure mechanism of the indicted component and integrate. New proper corrective actions were devised and successfully implemented.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris