Featured Application The proposed microphone-based diagnostic approach is suitable for non-contact condition monitoring of rolling bearings in industrial environments where the installation of contact sensors is impractical or unsafe. Potential applications include industrial machinery and retrofit monitoring of existing assets, where optimal microphone placement combined with HFRT-envelope-based analysis enables fault detection at a distance.Abstract Monitoring the condition of rolling bearings is critical for industrial reliability, yet traditional contact-based accelerometers can be impractical in confined or hazardous environments. This study investigates the use of microphones as a non-invasive diagnostic alternative, focusing on the impact of sensor distance and spatial placement on fault detection sensitivity across various rotational speeds and load conditions. Using an accelerometer mounted directly on the bearing as a benchmark, acoustic data were acquired on a test bench under different speed and load conditions. The experimental setup evaluated three distinct microphone positions and five distances relative to the source to assess spatial influence. Analysis was conducted comparing scalar indicators, such as Root Mean Square (RMS), kurtosis and Crest Factor (CF) values, with advanced diagnostic techniques, specifically the High-Frequency Resonance Technique (HFRT) for envelope spectrum extraction. Results indicate that while the signal-to-noise ratio (SNR) predictably decreases with distance, diagnostic performance is significantly compromised by acoustic shielding effects caused by bearing housing. Moreover, while simple statistical factors (RMS, kurtosis, CF) show limited reliability across varying distances and noise floors, HFRT-based envelope analysis yields robust fault identification even at the maximum sensor distance. The study concludes that optimal microphone placement is essential for reliable remote monitoring. Particularly, these findings suggest that a preliminary spatial characterization of the acoustic field can significantly enhance the effectiveness of non-contact diagnostic systems in industrial applications.

Non-Contact Bearing Fault Diagnostics: Experimental Investigation of Microphones Position and Distance / Voltolini, E., Toscani, A., Armelloni, E., Cocconcelli, M., Fendillo, L., Manconi, E.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 16:8(2026), pp. 1-19. [10.3390/app16083670]

Non-Contact Bearing Fault Diagnostics: Experimental Investigation of Microphones Position and Distance

Cocconcelli M.;Manconi E.
2026

Abstract

Featured Application The proposed microphone-based diagnostic approach is suitable for non-contact condition monitoring of rolling bearings in industrial environments where the installation of contact sensors is impractical or unsafe. Potential applications include industrial machinery and retrofit monitoring of existing assets, where optimal microphone placement combined with HFRT-envelope-based analysis enables fault detection at a distance.Abstract Monitoring the condition of rolling bearings is critical for industrial reliability, yet traditional contact-based accelerometers can be impractical in confined or hazardous environments. This study investigates the use of microphones as a non-invasive diagnostic alternative, focusing on the impact of sensor distance and spatial placement on fault detection sensitivity across various rotational speeds and load conditions. Using an accelerometer mounted directly on the bearing as a benchmark, acoustic data were acquired on a test bench under different speed and load conditions. The experimental setup evaluated three distinct microphone positions and five distances relative to the source to assess spatial influence. Analysis was conducted comparing scalar indicators, such as Root Mean Square (RMS), kurtosis and Crest Factor (CF) values, with advanced diagnostic techniques, specifically the High-Frequency Resonance Technique (HFRT) for envelope spectrum extraction. Results indicate that while the signal-to-noise ratio (SNR) predictably decreases with distance, diagnostic performance is significantly compromised by acoustic shielding effects caused by bearing housing. Moreover, while simple statistical factors (RMS, kurtosis, CF) show limited reliability across varying distances and noise floors, HFRT-based envelope analysis yields robust fault identification even at the maximum sensor distance. The study concludes that optimal microphone placement is essential for reliable remote monitoring. Particularly, these findings suggest that a preliminary spatial characterization of the acoustic field can significantly enhance the effectiveness of non-contact diagnostic systems in industrial applications.
2026
16
8
1
19
Non-Contact Bearing Fault Diagnostics: Experimental Investigation of Microphones Position and Distance / Voltolini, E., Toscani, A., Armelloni, E., Cocconcelli, M., Fendillo, L., Manconi, E.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 16:8(2026), pp. 1-19. [10.3390/app16083670]
Voltolini, E.; Toscani, A.; Armelloni, E.; Cocconcelli, M.; Fendillo, L.; Manconi, E.
File in questo prodotto:
File Dimensione Formato  
applsci-16-03670 (1).pdf

Open access

Tipologia: VOR - Versione pubblicata dall'editore
Licenza: [IR] creative-commons
Dimensione 5.62 MB
Formato Adobe PDF
5.62 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1407048
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact