Purpose: To assess intraobserver and interobserver agreement among physicians with different degrees of clinical experience, using a novel fundus autofluorescence semiautomated software for quantification of geographic atrophy in clinical setting. Methods: Fundus autofluorescence frames (excitation: 488 nm; emission: 500-700 nm) of 29 eyes (20 patients; mean age, 79.6 +/- 6.2 years) with geographic atrophy secondary to age-related macular degeneration, and no signs of choroidal neovascularization, were analyzed using Region Finder, a semiautomated software embedded in Spectralis (Heidelberg Engineering, Heidelberg, Germany). For each study eye, semiautomated atrophy identification and quantification were independently performed, twice (in a 2-week time frame), by 3 readers with different degrees of clinical experience (2 fellows, and 1 resident). Intraobserver and interobserver agreements were assessed. Results: Mean difference in intraobserver agreement (Bland-Altman statistics) ranged from -0.17 mm(2) to 0.13 mm(2). Intraobserver agreement was excellent until the geographic atrophy threshold value of 15.72 mm(2). Variability correlated with the size of atrophy. Mean difference in interobserver agreement (Bland-Altman statistics) ranged from -0.25 mm(2) to 0.27 mm(2), with no significant difference between senior and junior readers. Multifocal lesion or foveal involvement in atrophy was not the cause of disagreement. Conclusion: Region Finder is a reliable tool for the identification and quantification of geographic atrophy in patients with age-related macular degeneration, in a clinical setting even when performed by junior reader.

EVALUATION OF SEMIAUTOMATED MEASUREMENT OF GEOGRAPHIC ATROPHY IN AGE-RELATED MACULAR DEGENERATION BY FUNDUS AUTOFLUORESCENCE IN CLINICAL SETTING / Panthier, C., Querques, G., Puche, N., Le Tien, V., Garavito, R.b., Bechet, S., Massamba, N., Souied, E.h.. - In: RETINA. - ISSN 0275-004X. - 34:3(2014), pp. 576-582.

EVALUATION OF SEMIAUTOMATED MEASUREMENT OF GEOGRAPHIC ATROPHY IN AGE-RELATED MACULAR DEGENERATION BY FUNDUS AUTOFLUORESCENCE IN CLINICAL SETTING

QUERQUES , GIUSEPPE;
2014

Abstract

Purpose: To assess intraobserver and interobserver agreement among physicians with different degrees of clinical experience, using a novel fundus autofluorescence semiautomated software for quantification of geographic atrophy in clinical setting. Methods: Fundus autofluorescence frames (excitation: 488 nm; emission: 500-700 nm) of 29 eyes (20 patients; mean age, 79.6 +/- 6.2 years) with geographic atrophy secondary to age-related macular degeneration, and no signs of choroidal neovascularization, were analyzed using Region Finder, a semiautomated software embedded in Spectralis (Heidelberg Engineering, Heidelberg, Germany). For each study eye, semiautomated atrophy identification and quantification were independently performed, twice (in a 2-week time frame), by 3 readers with different degrees of clinical experience (2 fellows, and 1 resident). Intraobserver and interobserver agreements were assessed. Results: Mean difference in intraobserver agreement (Bland-Altman statistics) ranged from -0.17 mm(2) to 0.13 mm(2). Intraobserver agreement was excellent until the geographic atrophy threshold value of 15.72 mm(2). Variability correlated with the size of atrophy. Mean difference in interobserver agreement (Bland-Altman statistics) ranged from -0.25 mm(2) to 0.27 mm(2), with no significant difference between senior and junior readers. Multifocal lesion or foveal involvement in atrophy was not the cause of disagreement. Conclusion: Region Finder is a reliable tool for the identification and quantification of geographic atrophy in patients with age-related macular degeneration, in a clinical setting even when performed by junior reader.
2014
34
3
576
582
EVALUATION OF SEMIAUTOMATED MEASUREMENT OF GEOGRAPHIC ATROPHY IN AGE-RELATED MACULAR DEGENERATION BY FUNDUS AUTOFLUORESCENCE IN CLINICAL SETTING / Panthier, C., Querques, G., Puche, N., Le Tien, V., Garavito, R.b., Bechet, S., Massamba, N., Souied, E.h.. - In: RETINA. - ISSN 0275-004X. - 34:3(2014), pp. 576-582.
Panthier, C; Querques, Giuseppe; Puche, N; Le Tien, V; Garavito, Rb; Bechet, S; Massamba, N; Souied, Eh
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1404515
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 28
social impact