The usage of multi-physics simulation tools is steadily increasing in the field of electrochemistry. While this is a great opportunity for closing the gap between analytical electrochemists used to simple 1D models and exper-imentalists, there are possible pitfalls that must be avoided. In this work, we raise awareness on numerical ar-tifacts that can mislead the interpretation of cyclic voltammetry experiments through simulations of geometries with different number of spatial dimensions. In particular, we show that one-dimensional simulations can suffer from substantial errors when models go beyond charge neutrality assumption. We exemplify such situations using simple electrolyte/electrode structures with 1D, 2D and 3D geometries. We then show the occurrence of artifacts related to the geometry of the simulation domain on the simulation of cyclic voltammetric curves as those typically performed to characterize conjugated polymer/electrolyte blends. All the models are imple-mented using COMSOL Multiphysics and are accompanied by a detailed description of their implementation. However, geometrical artifacts identified in this work also apply to other simulation approaches.
Reproducing capacitive cyclic voltammetric curves by simulation: When are simplified geometries appropriate? / Mele, Lj; Verardo, C; Palestri, P. - In: ELECTROCHEMISTRY COMMUNICATIONS. - ISSN 1388-2481. - 142:(2022), pp. 107378-N/A. [10.1016/j.elecom.2022.107378]
Reproducing capacitive cyclic voltammetric curves by simulation: When are simplified geometries appropriate?
Palestri, P
2022
Abstract
The usage of multi-physics simulation tools is steadily increasing in the field of electrochemistry. While this is a great opportunity for closing the gap between analytical electrochemists used to simple 1D models and exper-imentalists, there are possible pitfalls that must be avoided. In this work, we raise awareness on numerical ar-tifacts that can mislead the interpretation of cyclic voltammetry experiments through simulations of geometries with different number of spatial dimensions. In particular, we show that one-dimensional simulations can suffer from substantial errors when models go beyond charge neutrality assumption. We exemplify such situations using simple electrolyte/electrode structures with 1D, 2D and 3D geometries. We then show the occurrence of artifacts related to the geometry of the simulation domain on the simulation of cyclic voltammetric curves as those typically performed to characterize conjugated polymer/electrolyte blends. All the models are imple-mented using COMSOL Multiphysics and are accompanied by a detailed description of their implementation. However, geometrical artifacts identified in this work also apply to other simulation approaches.File | Dimensione | Formato | |
---|---|---|---|
MeleEC2022.pdf
Open access
Tipologia:
Versione pubblicata dall'editore
Dimensione
638.31 kB
Formato
Adobe PDF
|
638.31 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris