The failure modes of K-joints of Concrete Filled Steel Tubular (CFST) truss structures were investigated through laboratory tests. CFST K-joint specimens consisted of a tubular chord filled with concrete and two braces inclined at the same angle with respect to the chord. Their size was chosen of the same scale as that of joints of real tubular structures currently used in bridges. The results were compared with those obtained by testing K-joint specimens of Circular Hollow Section (CHS) truss structures with the same size. Contrary to CHS K-joints, where a chord face failure mode occurred, in CFST K-joints no failure mode with inward deformation of the chord section can occur. Hence, punching shear failure was shown to be the typical failure mode of CFST K-joints, if no brace failure mode occurred before. Resistance of CFST K-joints to punching shear was then compared with the resistance values calculated through the Eurocode 3 and the AWS code formulae on CHS K-joints. The values provided by the former formula were quite close to (although always lower than) the actual resistance to punching shear of CFST K-joints. Finally, the favourable effect on joint resistance due to additional studs welded to the interior surface of the chord tube of CFST K-joint was also investigated.
Experimental study on K-joints of concrete-filled steel tubular truss structures / Briseghella, Bruno. - In: JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH. - ISSN 0143-974X. - 107:(2015), pp. 182-193. [10.1016/j.jcsr.2015.01.023]
Experimental study on K-joints of concrete-filled steel tubular truss structures
BRISEGHELLA
2015
Abstract
The failure modes of K-joints of Concrete Filled Steel Tubular (CFST) truss structures were investigated through laboratory tests. CFST K-joint specimens consisted of a tubular chord filled with concrete and two braces inclined at the same angle with respect to the chord. Their size was chosen of the same scale as that of joints of real tubular structures currently used in bridges. The results were compared with those obtained by testing K-joint specimens of Circular Hollow Section (CHS) truss structures with the same size. Contrary to CHS K-joints, where a chord face failure mode occurred, in CFST K-joints no failure mode with inward deformation of the chord section can occur. Hence, punching shear failure was shown to be the typical failure mode of CFST K-joints, if no brace failure mode occurred before. Resistance of CFST K-joints to punching shear was then compared with the resistance values calculated through the Eurocode 3 and the AWS code formulae on CHS K-joints. The values provided by the former formula were quite close to (although always lower than) the actual resistance to punching shear of CFST K-joints. Finally, the favourable effect on joint resistance due to additional studs welded to the interior surface of the chord tube of CFST K-joint was also investigated.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0143974X15000255-main.pdf
Accesso riservato
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
2.59 MB
Formato
Adobe PDF
|
2.59 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
JCSR+testo+con+figure.pdf
Open access
Tipologia:
AAM - Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione
15.28 MB
Formato
Adobe PDF
|
15.28 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris