The unibody (Powerlink/AFX/AFX2) Endovascular AAA device (Endologix Inc., CA, USA) presents a unique design with its long main body and two innate limbs. The device is designed to be deployed and sits on the native aortoiliac bifurcation and represents the only one-piece bifurcated endograft designed to use anatomical fixation for endograft stabilization. According to published literature, the unibody device seems to represent a valid choice in the treatment of abdominal aortic aneurysms. This particular device would seem to satisfactorily perform even in the treatment of more compressed aneurysms (also in off-label association with parallel grafts) and in occlusive pathologies. Ongoing studies will provide new real-life data in a large and unselected patient population to better understand the device's advantages and limitations.

Unibody bifurcated aortic endograft: Device description, review of the literature and future perspectives / Sirignano, P.; Silingardi, R.; Mansour, W.; Andreoli, F.; Migliari, M.; Speziale, F.. - In: FUTURE CARDIOLOGY. - ISSN 1479-6678. - 17:5(2021), pp. 793-804. [10.2217/fca-2020-0119]

Unibody bifurcated aortic endograft: Device description, review of the literature and future perspectives

Silingardi R.;Andreoli F.;Migliari M.;
2021

Abstract

The unibody (Powerlink/AFX/AFX2) Endovascular AAA device (Endologix Inc., CA, USA) presents a unique design with its long main body and two innate limbs. The device is designed to be deployed and sits on the native aortoiliac bifurcation and represents the only one-piece bifurcated endograft designed to use anatomical fixation for endograft stabilization. According to published literature, the unibody device seems to represent a valid choice in the treatment of abdominal aortic aneurysms. This particular device would seem to satisfactorily perform even in the treatment of more compressed aneurysms (also in off-label association with parallel grafts) and in occlusive pathologies. Ongoing studies will provide new real-life data in a large and unselected patient population to better understand the device's advantages and limitations.
2021
17
5
793
804
Unibody bifurcated aortic endograft: Device description, review of the literature and future perspectives / Sirignano, P.; Silingardi, R.; Mansour, W.; Andreoli, F.; Migliari, M.; Speziale, F.. - In: FUTURE CARDIOLOGY. - ISSN 1479-6678. - 17:5(2021), pp. 793-804. [10.2217/fca-2020-0119]
Sirignano, P.; Silingardi, R.; Mansour, W.; Andreoli, F.; Migliari, M.; Speziale, F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1259590
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact