Ventilated tile roofs are common objects in the construction sector of Italy. A preferred type is characterized by a ventilated air space between the upper tile layer and the roof structure below. The air enters through openings at the gutters level, flows up below sheathing in the air space along the pitch and is finally discharged through openings along the ridge. This setup, which leaves the room below the roof sealed and habitable, allows removing the heat brought by the absorbed solar radiation thanks to the flow that is established by natural ventilation in the air space. However, its actual performance is often weak and also unpredictable due to continuously changing buoyancy forces. Nonetheless, a permanent and adequate flow can be ensured even through a relatively thin air space and for whichever irradiance and wind conditions by forced ventilation: a properly designed fan can provide the desired flow rate by extracting the air after this is collected along the ridge by a manifold. A thorough design and manufacturing of the manifold is needed, however, to avoid a highly inhomogeneous flow, which would follow the easiest path and leave most of the pitch practically unventilated. As an alternative, a throttling shutter parallel to the ridge has been proposed to progressively choke the flow entering the manifold through parallel climbing ducts as the fan is approached, possibly allowing onsite adjustment after installation. In this work the solution, developed by means of a small scale test bed, is illustrated in details and some methods to assess the performance are presented.

Ventilated pitched roof with forced ventilation and flow homogenizer device: Testing and performance assessment / Ferrari, C.; Muscio, A.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1224:1(2019), p. 012027. (Intervento presentato al convegno 36th UIT Heat Transfer Conference tenutosi a Four Points by Sheraton Hotel, ita nel 2018) [10.1088/1742-6596/1224/1/012027].

Ventilated pitched roof with forced ventilation and flow homogenizer device: Testing and performance assessment

Ferrari C.;Muscio A.
2019

Abstract

Ventilated tile roofs are common objects in the construction sector of Italy. A preferred type is characterized by a ventilated air space between the upper tile layer and the roof structure below. The air enters through openings at the gutters level, flows up below sheathing in the air space along the pitch and is finally discharged through openings along the ridge. This setup, which leaves the room below the roof sealed and habitable, allows removing the heat brought by the absorbed solar radiation thanks to the flow that is established by natural ventilation in the air space. However, its actual performance is often weak and also unpredictable due to continuously changing buoyancy forces. Nonetheless, a permanent and adequate flow can be ensured even through a relatively thin air space and for whichever irradiance and wind conditions by forced ventilation: a properly designed fan can provide the desired flow rate by extracting the air after this is collected along the ridge by a manifold. A thorough design and manufacturing of the manifold is needed, however, to avoid a highly inhomogeneous flow, which would follow the easiest path and leave most of the pitch practically unventilated. As an alternative, a throttling shutter parallel to the ridge has been proposed to progressively choke the flow entering the manifold through parallel climbing ducts as the fan is approached, possibly allowing onsite adjustment after installation. In this work the solution, developed by means of a small scale test bed, is illustrated in details and some methods to assess the performance are presented.
2019
36th UIT Heat Transfer Conference
Four Points by Sheraton Hotel, ita
2018
1224
012027
Ferrari, C.; Muscio, A.
Ventilated pitched roof with forced ventilation and flow homogenizer device: Testing and performance assessment / Ferrari, C.; Muscio, A.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1224:1(2019), p. 012027. (Intervento presentato al convegno 36th UIT Heat Transfer Conference tenutosi a Four Points by Sheraton Hotel, ita nel 2018) [10.1088/1742-6596/1224/1/012027].
File in questo prodotto:
File Dimensione Formato  
Ferrari_2019_J._Phys. _Conf._Ser._1224_012027.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1221445
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact