An unusual complication of percutaneous fixation of a schapoid fracture in a 36-year-old man is described. After this surgery, the patient complained of numbness and tingling within the median nerve distribution and thenar weakness. An Electromyography showing moderate CTS had led to carpal tunnel decompression, which resulted unsuccessful. When the patient presented to us, both sensory and motor median nerve impairment were present, interfering with his professional activity. A computed tomography scan performed to assess the scaphoid screw position, showed that the screw had been placed volar to the scaphoid, adjacent to the median nerve. Surgery confirmed median nerve compression by the screw, especially during complete wrist extension. The surgical removal of the screw led to immediate improvement of both the motor and sensory functions of the nerve, with complete clinical restoration of nerve function and resolution of the symptoms 2 months postoperatively.
Median nerve injury caused by screw malpositioning in percutaneous scaphoid fracture fixation / Starnoni, M.; Colzani, G.; De Santis, G.; Acciaro, A. L.. - In: PLASTIC AND RECONSTRUCTIVE SURGERY – GLOBAL OPEN. - ISSN 2169-7574. - 7:6(2019), pp. 1-3. [10.1097/GOX.0000000000002292]
Median nerve injury caused by screw malpositioning in percutaneous scaphoid fracture fixation
Starnoni, M.;De Santis, G.;Acciaro A. L.
2019
Abstract
An unusual complication of percutaneous fixation of a schapoid fracture in a 36-year-old man is described. After this surgery, the patient complained of numbness and tingling within the median nerve distribution and thenar weakness. An Electromyography showing moderate CTS had led to carpal tunnel decompression, which resulted unsuccessful. When the patient presented to us, both sensory and motor median nerve impairment were present, interfering with his professional activity. A computed tomography scan performed to assess the scaphoid screw position, showed that the screw had been placed volar to the scaphoid, adjacent to the median nerve. Surgery confirmed median nerve compression by the screw, especially during complete wrist extension. The surgical removal of the screw led to immediate improvement of both the motor and sensory functions of the nerve, with complete clinical restoration of nerve function and resolution of the symptoms 2 months postoperatively.File | Dimensione | Formato | |
---|---|---|---|
Median_Nerve_Injury_Caused_by_Screw_Malpositioning.35.pdf
Open access
Tipologia:
Versione pubblicata dall'editore
Dimensione
987.2 kB
Formato
Adobe PDF
|
987.2 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris