The aim of the study was to compare the effect of Self-Adjusting Files (SAF) and WaveOne Primary file with syringe and needle irrigation on the filling ability of oval-shaped root canals obturated with thermoplasticized gutta-percha. Twenty-four single root teeth with single oval-shaped root canals were distributed in two experimental homogeneous group. One group was instrumented and cleansed using the SAF system while in the other group the WaveOne system with syringe and needle irrigation was used. After instrumentation, the roots were filled by Thermafil Obturators and TopSeal sealer. Specimens were transversally sectioned at 2-, 5- and 7-mm levels from the apex and observed under light microscope. The percentage of gutta-percha filled area (PGFA), the percentage of sealer filled area (PSFA) and the percentage of voids area (PVA) were measured for each section, moreover the percentage of completely filled sections was evaluated. At all levels, no significant differences in terms of PGFA, PSFA, PVA and percentage of completely filled canals between groups were obtained (P > .05). On the contrary, when the data were pooled, the mean PGFA in the SAF group was 95.8%, whereas it was 93.2% in the WaveOne group (P < 0.05). The percentage of sections completely filled was 77.8% in the SAF group, while 52.8% in the WaveOne group (P < 0.05). Overall, the use of the SAF system in oval canals allows to obtain a significantly greater complete filling than the use of the WaveOne system.

Effect of Self-Adjusting file and WaveOne reciprocating file on the filling ability of oval-shaped canals with thermoplasticized gutta-percha / Generali, L; Cavani, F; Righi, E; Murri Dello Diago, A; Spinas, E; Giannetti, L. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 32:6(2018), pp. 1583-1587.

Effect of Self-Adjusting file and WaveOne reciprocating file on the filling ability of oval-shaped canals with thermoplasticized gutta-percha

Generali L
;
Cavani F;Righi E;Giannetti L
2018

Abstract

The aim of the study was to compare the effect of Self-Adjusting Files (SAF) and WaveOne Primary file with syringe and needle irrigation on the filling ability of oval-shaped root canals obturated with thermoplasticized gutta-percha. Twenty-four single root teeth with single oval-shaped root canals were distributed in two experimental homogeneous group. One group was instrumented and cleansed using the SAF system while in the other group the WaveOne system with syringe and needle irrigation was used. After instrumentation, the roots were filled by Thermafil Obturators and TopSeal sealer. Specimens were transversally sectioned at 2-, 5- and 7-mm levels from the apex and observed under light microscope. The percentage of gutta-percha filled area (PGFA), the percentage of sealer filled area (PSFA) and the percentage of voids area (PVA) were measured for each section, moreover the percentage of completely filled sections was evaluated. At all levels, no significant differences in terms of PGFA, PSFA, PVA and percentage of completely filled canals between groups were obtained (P > .05). On the contrary, when the data were pooled, the mean PGFA in the SAF group was 95.8%, whereas it was 93.2% in the WaveOne group (P < 0.05). The percentage of sections completely filled was 77.8% in the SAF group, while 52.8% in the WaveOne group (P < 0.05). Overall, the use of the SAF system in oval canals allows to obtain a significantly greater complete filling than the use of the WaveOne system.
2018
32
6
1583
1587
Effect of Self-Adjusting file and WaveOne reciprocating file on the filling ability of oval-shaped canals with thermoplasticized gutta-percha / Generali, L; Cavani, F; Righi, E; Murri Dello Diago, A; Spinas, E; Giannetti, L. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 32:6(2018), pp. 1583-1587.
Generali, L; Cavani, F; Righi, E; Murri Dello Diago, A; Spinas, E; Giannetti, L
File in questo prodotto:
File Dimensione Formato  
Effect of Self-Adjusting file and WaveOne reciprocating file.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 2.07 MB
Formato Adobe PDF
2.07 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1171213
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact