This study presents a comprehensive approach for calculating buildings' energy contribution to the formation of urban heat island (UHI). For this purpose, the heat released by building envelope and HVAC system has been taken into account, while longwave radiation to the sky has been excluded from the calculation, as it is not so relevant to the UHI effect. Several strategies to minimize the UHI phenomenon and their effects on the heat released have been considered along the whole-year period. An existing educational building has been selected as case study. The selected building is considered representative for a wide range of tertiary buildings with an intermittent operation mode. Results have been obtained by dynamic simulation models, which have been validated with measured indoor air temperature data. Despite a moderate reduction of the energy contribution to the UHI effect during winter, which is commonly considered unfavorable, the effectiveness of cool coating application in reducing the heat released during summer has been clearly demonstrated. On the other hand, it was found that a higher level of envelope insulation is not yielding a significant reduction of the heat released, especially during summer.
Dynamic analysis of the heat released by tertiary buildings and the effects of urban heat island mitigation strategies / Magli, Susanna; Lodi, Chiara; Contini, Francesco Maria; Muscio, Alberto; Tartarini, Paolo. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - 114:(2016), pp. 164-172. [10.1016/j.enbuild.2015.05.037]
Dynamic analysis of the heat released by tertiary buildings and the effects of urban heat island mitigation strategies
MAGLI, SUSANNA;LODI, Chiara;CONTINI, Francesco Maria;MUSCIO, Alberto;TARTARINI, Paolo
2016
Abstract
This study presents a comprehensive approach for calculating buildings' energy contribution to the formation of urban heat island (UHI). For this purpose, the heat released by building envelope and HVAC system has been taken into account, while longwave radiation to the sky has been excluded from the calculation, as it is not so relevant to the UHI effect. Several strategies to minimize the UHI phenomenon and their effects on the heat released have been considered along the whole-year period. An existing educational building has been selected as case study. The selected building is considered representative for a wide range of tertiary buildings with an intermittent operation mode. Results have been obtained by dynamic simulation models, which have been validated with measured indoor air temperature data. Despite a moderate reduction of the energy contribution to the UHI effect during winter, which is commonly considered unfavorable, the effectiveness of cool coating application in reducing the heat released during summer has been clearly demonstrated. On the other hand, it was found that a higher level of envelope insulation is not yielding a significant reduction of the heat released, especially during summer.File | Dimensione | Formato | |
---|---|---|---|
2016-02_Energy&Buildings 114_pp164-172.pdf
Accesso riservato
Descrizione: Articolo principale
Tipologia:
Versione pubblicata dall'editore
Dimensione
3.54 MB
Formato
Adobe PDF
|
3.54 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
POST PRINT_ Dynamic analysis of the heat released by tertiary.pdf
Open access
Tipologia:
Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione
919.09 kB
Formato
Adobe PDF
|
919.09 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris