The purpose of the study was to evaluate survival and peri-implant bone levels of single, immediately loaded post-extractive implants in the anterior maxilla 12 months after implant placement. Thirty-six consecutive patients from 3 study centers were included in the study. The concerned sites were upper premolars, canines, and incisors. For each patient the following data were recorded: reason for tooth extraction, bone quality, implant size, and final insertion torque. Implants were placed using a flapless technique and immediately loaded with a nonoccluding temporary restoration. Final restorations were provided 4 months later. Peri-implant bone resorption was evaluated radiographically after 6 and 12 months. The average final insertion torque was 70.55 Ncm. One implant inserted in D3 quality bone with a 35-Ncm seating torque was lost. All other implants had a final insertion torque ranging between 50 and 80 Ncm. The average peri-implant bone loss was 0.437 and 0.507 mm at 6 and 12 months, respectively. All the sites maintained excellent papillae and peri-implant soft-tissue conditions. The resulting 1-year success rate was 97.2%. Immediate nonfunctional loading of single postextractive implants in the anterior maxilla is a predictable treatment. And it seems that achieving high insertion torques by placing self-tapping/self-condensing implants in an underprepared osteotomy is favorable.

Immediate loading of single post-extractive implants in the anterior maxilla: 12-month results from a multicenter clinical study / Grandi, Tommaso; Garuti, Giovanna; Samarani, Rawad; Guazzi, Paolo; Forabosco, Andrea. - In: JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 0160-6972. - 38:1(2012), pp. 477-484. [10.1563/AAID-JOI-D-11-00058]

Immediate loading of single post-extractive implants in the anterior maxilla: 12-month results from a multicenter clinical study

GRANDI, Tommaso;GARUTI, GIOVANNA;FORABOSCO, Andrea
2012

Abstract

The purpose of the study was to evaluate survival and peri-implant bone levels of single, immediately loaded post-extractive implants in the anterior maxilla 12 months after implant placement. Thirty-six consecutive patients from 3 study centers were included in the study. The concerned sites were upper premolars, canines, and incisors. For each patient the following data were recorded: reason for tooth extraction, bone quality, implant size, and final insertion torque. Implants were placed using a flapless technique and immediately loaded with a nonoccluding temporary restoration. Final restorations were provided 4 months later. Peri-implant bone resorption was evaluated radiographically after 6 and 12 months. The average final insertion torque was 70.55 Ncm. One implant inserted in D3 quality bone with a 35-Ncm seating torque was lost. All other implants had a final insertion torque ranging between 50 and 80 Ncm. The average peri-implant bone loss was 0.437 and 0.507 mm at 6 and 12 months, respectively. All the sites maintained excellent papillae and peri-implant soft-tissue conditions. The resulting 1-year success rate was 97.2%. Immediate nonfunctional loading of single postextractive implants in the anterior maxilla is a predictable treatment. And it seems that achieving high insertion torques by placing self-tapping/self-condensing implants in an underprepared osteotomy is favorable.
2012
38
1
477
484
Immediate loading of single post-extractive implants in the anterior maxilla: 12-month results from a multicenter clinical study / Grandi, Tommaso; Garuti, Giovanna; Samarani, Rawad; Guazzi, Paolo; Forabosco, Andrea. - In: JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 0160-6972. - 38:1(2012), pp. 477-484. [10.1563/AAID-JOI-D-11-00058]
Grandi, Tommaso; Garuti, Giovanna; Samarani, Rawad; Guazzi, Paolo; Forabosco, Andrea
File in questo prodotto:
File Dimensione Formato  
aaid-joi-d-11-00058.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 352.99 kB
Formato Adobe PDF
352.99 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1085322
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 16
social impact