Purpose: Cone beam computed tomography (CBCT) and microradiographic analyses were comparatively performed in maxillary sinus augmentation to preliminarily verify the diagnostic potential of CBCT on the evaluation of bone regeneration. Materials and Methods: A two-stage protocol was conducted in 19 consenting patients, all having the crestal bone ≤2mm, in private dental office. Mineralized human bone allograft particles were used to augment sinus using lateral window approach. A succession of CBCT scans of the maxilla was taken before surgery, after sinus augmentation, and immediately after implant insertion. Using virtual probes, CBCT data were processed by medical imaging software and expressed as gray level (GL). A bone core biopsy was taken at implant placement, 6 months after surgery. Microradiography of transverse sections, taken 6, 8, and 10mm from the crestal surface, of methacrylate-embedded biopsies was performed to analyze and to evaluate the mineralized material amount (MM%). Results: A total of 21 sinus augmentations were performed. CBCT (mean GL: 646-693) data were not statistically different when comparing 6-, 8-, and 10-mm sites to after grafting/implant-insertion values. Furthermore, microradiographic (mean MM%: 45.3-48.3) data were not statistically different comparing 6-, 8-, and 10-mm sites, due to variation of values among patients. A GL and MM% parallelism was identified considering each patient, instead. A significant correlation (p<.001) between GL and MM% was found after both Wilcoxon test for paired data and simple linear regression analysis. Conclusions: The preliminary result clearly demonstrated the predictability of the CBCT analysis. Due to the limited sample and great variations of the MM% recorded in patients, further clinical and morphometric studies are needed to fulfill diagnostic expectations. © 2012 Wiley Periodicals, Inc.

Quantitative Comparison of Cone Beam Computed Tomography and Microradiography in the Evaluation of Bone Density after Maxillary Sinus Augmentation: A Preliminary Study / Soardi, Cm; Zaffe, Davide; Motroni, A; Wang, H. L.. - In: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH. - ISSN 1523-0899. - STAMPA. - 16:4(2014), pp. 557-564. [10.1111/cid.12016]

Quantitative Comparison of Cone Beam Computed Tomography and Microradiography in the Evaluation of Bone Density after Maxillary Sinus Augmentation: A Preliminary Study.

ZAFFE, Davide;
2014

Abstract

Purpose: Cone beam computed tomography (CBCT) and microradiographic analyses were comparatively performed in maxillary sinus augmentation to preliminarily verify the diagnostic potential of CBCT on the evaluation of bone regeneration. Materials and Methods: A two-stage protocol was conducted in 19 consenting patients, all having the crestal bone ≤2mm, in private dental office. Mineralized human bone allograft particles were used to augment sinus using lateral window approach. A succession of CBCT scans of the maxilla was taken before surgery, after sinus augmentation, and immediately after implant insertion. Using virtual probes, CBCT data were processed by medical imaging software and expressed as gray level (GL). A bone core biopsy was taken at implant placement, 6 months after surgery. Microradiography of transverse sections, taken 6, 8, and 10mm from the crestal surface, of methacrylate-embedded biopsies was performed to analyze and to evaluate the mineralized material amount (MM%). Results: A total of 21 sinus augmentations were performed. CBCT (mean GL: 646-693) data were not statistically different when comparing 6-, 8-, and 10-mm sites to after grafting/implant-insertion values. Furthermore, microradiographic (mean MM%: 45.3-48.3) data were not statistically different comparing 6-, 8-, and 10-mm sites, due to variation of values among patients. A GL and MM% parallelism was identified considering each patient, instead. A significant correlation (p<.001) between GL and MM% was found after both Wilcoxon test for paired data and simple linear regression analysis. Conclusions: The preliminary result clearly demonstrated the predictability of the CBCT analysis. Due to the limited sample and great variations of the MM% recorded in patients, further clinical and morphometric studies are needed to fulfill diagnostic expectations. © 2012 Wiley Periodicals, Inc.
2014
16
4
557
564
Quantitative Comparison of Cone Beam Computed Tomography and Microradiography in the Evaluation of Bone Density after Maxillary Sinus Augmentation: A Preliminary Study / Soardi, Cm; Zaffe, Davide; Motroni, A; Wang, H. L.. - In: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH. - ISSN 1523-0899. - STAMPA. - 16:4(2014), pp. 557-564. [10.1111/cid.12016]
Soardi, Cm; Zaffe, Davide; Motroni, A; Wang, H. L.
File in questo prodotto:
File Dimensione Formato  
2014Soardi CIDRR.pdf

Accesso riservato

Descrizione: Articolo principale
Tipologia: Versione pubblicata dall'editore
Dimensione 430.17 kB
Formato Adobe PDF
430.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/954492
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact