Objective: In a previous study, Human gingival fibroblasts cultured in vitro have been exposed directly to Elite Implant (Zhermack, Badia Polesine, Rovigo). The gingival fibroblasts proliferation and vitality are unaffected by the presence of Elite Implant. The aim of this study is to evaluate the clinical efficacy of this elastomeric sterile and radiopaque impression material, indicated for the immediate implant loading protocol. Materials and Methods: A case series of 14 cases of implant rehabilitation treated with immediate loading protocol have been followed for 20 months. Results: Out of 62 implant placed we had 1 failure (98,4% success) and no prosthetic failures; the use of this material allowed us to control if in the post surgical radiographs was present a radiopacity of the trapped material; this event didn't happened. Conclusions: This impression material may represent a safe medical device for clinical and surgical applications. In addition, this material is radiopaque and, thus, can be identified radiographically.
Clinical efficacy of an implant impression material (Elite Implant) for immediate loading:case series / Bortolini, Sergio; Berzaghi, Andrea; Natali, Alfredo; Martinolli, Matteo; Paiardi, Maurizio; Consolo, Ugo. - In: EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 1756-2406. - ELETTRONICO. - 6(suppl):(2013), pp. S61-S61. (Intervento presentato al convegno XXI Congresso SIO – Il Trattamento Implantare tra le Innovazioni tecnologiche e I Cambiamenti Socio-economici tenutosi a Milano nel 8-9 Febbraio 2013).
Clinical efficacy of an implant impression material (Elite Implant) for immediate loading:case series.
BORTOLINI, Sergio;BERZAGHI, Andrea;NATALI, Alfredo;MARTINOLLI, MATTEO;PAIARDI, MAURIZIO;CONSOLO, Ugo
2013
Abstract
Objective: In a previous study, Human gingival fibroblasts cultured in vitro have been exposed directly to Elite Implant (Zhermack, Badia Polesine, Rovigo). The gingival fibroblasts proliferation and vitality are unaffected by the presence of Elite Implant. The aim of this study is to evaluate the clinical efficacy of this elastomeric sterile and radiopaque impression material, indicated for the immediate implant loading protocol. Materials and Methods: A case series of 14 cases of implant rehabilitation treated with immediate loading protocol have been followed for 20 months. Results: Out of 62 implant placed we had 1 failure (98,4% success) and no prosthetic failures; the use of this material allowed us to control if in the post surgical radiographs was present a radiopacity of the trapped material; this event didn't happened. Conclusions: This impression material may represent a safe medical device for clinical and surgical applications. In addition, this material is radiopaque and, thus, can be identified radiographically.File | Dimensione | Formato | |
---|---|---|---|
U-GOV 928495 e U-GOV 928496 Eur. J. Oral Implantology S61 e S62.pdf
Accesso riservato
Tipologia:
Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione
3.37 MB
Formato
Adobe PDF
|
3.37 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris