Objectives: To assess the reliability of bioelectric impedance analysis (BIA) for predicting total body water (TBW) and extracellular water (ECW) in obese children. Design: Comparison of five prediction models based on: (i) body weight (Wt), (ii) the impedance (Z) index (ZI=height(2)/Z), (iii) the association of Wt and ZI, (iv) the body surface area (SA) to impedance ratio (SA:Z) and, (v) the body volume (V) to impedance ratio (V:Z). Subjects: Thirty obese and 25 control children of 11.2+/-1.8 y of age. Measurements: TBW and ECW were assessed by deuterium and bromide dilution; Z was measured at frequencies of 5, 50 and 100 kHz. Results: In controls, Wt explained 11% more variance of TBW than ZI (r(2)=0.977, SEE=0.9 I, CV=3.8%) and the association of Wt and ZI improved the prediction of TBW only slightly (r(2)=0.982, SEE=0.8 I, CV=3.5%). The SA:Z and V:Z indexes explained 6 and 33% less variance of TBW respectively as compared to Wt alone. In obese subjects, ZI explained 4% more variance of TBW than Wt (r(2)=0.914, SEE=1.8 I, CV=6.4%) and the SA:Z ratio was the most accurate predictor of TBW (r(2)=0.959, SEE=1.2 l, CV=4.4%). However, the increase in the explained variance of TBW associated to the use of the SA:Z ratio was of only 1% as compared to the association of ZI and Wt. The V:Z ratio explained 9% less of variance of TBW as compared to ZI. In both control and obese subjects, the association of Wt and ZI offered the best prediction of ECW (r(2)=0.807, SEE=1.564 I and r(2)=0.826, SEE=1.035 I, respectively). However, the values of CV were much higher in controls than in obese children (17.5% vs 8.4%) owing to their lower ECW and greater variability in ECW%. ZI was the most accurate predictor of TBW on the pooled sample (n=55; r(2)=0.910, SEE=1.932 I, CV=7.4%). However, it was a poor predictor of ECW on the same sample owing to its high CV (n=55; r(2)=0.866, SEE =1.806 I, CV=17.0%). Conclusions: The body surface area to impedance ratio is the most accurate predictor of TBW in obese children but the association of ZI and Wt may be of more interest when BIA is used to estimate both TBW and ECW. The impedance index offers a good prediction of TBW but not of ECW in children with different levels of fatness.

The prediction of total body water and extracellular water from bioelectric impedance in obese children / Bedogni, G; Bollea, Mr; Severi, S; Trunfio, Ornella; Manzieri, Am; Battistini, Nino Carlo. - In: EUROPEAN JOURNAL OF CLINICAL NUTRITION. - ISSN 0954-3007. - STAMPA. - 51:(1997), pp. 129-133.

The prediction of total body water and extracellular water from bioelectric impedance in obese children

TRUNFIO, Ornella;BATTISTINI, Nino Carlo
1997

Abstract

Objectives: To assess the reliability of bioelectric impedance analysis (BIA) for predicting total body water (TBW) and extracellular water (ECW) in obese children. Design: Comparison of five prediction models based on: (i) body weight (Wt), (ii) the impedance (Z) index (ZI=height(2)/Z), (iii) the association of Wt and ZI, (iv) the body surface area (SA) to impedance ratio (SA:Z) and, (v) the body volume (V) to impedance ratio (V:Z). Subjects: Thirty obese and 25 control children of 11.2+/-1.8 y of age. Measurements: TBW and ECW were assessed by deuterium and bromide dilution; Z was measured at frequencies of 5, 50 and 100 kHz. Results: In controls, Wt explained 11% more variance of TBW than ZI (r(2)=0.977, SEE=0.9 I, CV=3.8%) and the association of Wt and ZI improved the prediction of TBW only slightly (r(2)=0.982, SEE=0.8 I, CV=3.5%). The SA:Z and V:Z indexes explained 6 and 33% less variance of TBW respectively as compared to Wt alone. In obese subjects, ZI explained 4% more variance of TBW than Wt (r(2)=0.914, SEE=1.8 I, CV=6.4%) and the SA:Z ratio was the most accurate predictor of TBW (r(2)=0.959, SEE=1.2 l, CV=4.4%). However, the increase in the explained variance of TBW associated to the use of the SA:Z ratio was of only 1% as compared to the association of ZI and Wt. The V:Z ratio explained 9% less of variance of TBW as compared to ZI. In both control and obese subjects, the association of Wt and ZI offered the best prediction of ECW (r(2)=0.807, SEE=1.564 I and r(2)=0.826, SEE=1.035 I, respectively). However, the values of CV were much higher in controls than in obese children (17.5% vs 8.4%) owing to their lower ECW and greater variability in ECW%. ZI was the most accurate predictor of TBW on the pooled sample (n=55; r(2)=0.910, SEE=1.932 I, CV=7.4%). However, it was a poor predictor of ECW on the same sample owing to its high CV (n=55; r(2)=0.866, SEE =1.806 I, CV=17.0%). Conclusions: The body surface area to impedance ratio is the most accurate predictor of TBW in obese children but the association of ZI and Wt may be of more interest when BIA is used to estimate both TBW and ECW. The impedance index offers a good prediction of TBW but not of ECW in children with different levels of fatness.
1997
51
129
133
The prediction of total body water and extracellular water from bioelectric impedance in obese children / Bedogni, G; Bollea, Mr; Severi, S; Trunfio, Ornella; Manzieri, Am; Battistini, Nino Carlo. - In: EUROPEAN JOURNAL OF CLINICAL NUTRITION. - ISSN 0954-3007. - STAMPA. - 51:(1997), pp. 129-133.
Bedogni, G; Bollea, Mr; Severi, S; Trunfio, Ornella; Manzieri, Am; Battistini, Nino Carlo
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/9156
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 21
social impact