Many transformerless topologies for photovoltaic systems were proposed in order to minimize power losses and avoid high levels of ground leakage current (that can arise in such systems). The most efficient PWM strategies achieve this goal by decoupling the grid from the DC Link during the freewheeling phases of the output current. These strategies usually operate only with a unity power factor. However, as solar inverters have penetrated into power distribution networks, new issues have arisen and modifications of regulations governing grid connection of distributed systems were introduced in some countries. One of the new requirements for the inverters connected to the low-voltage grids is the possibility to provide reactive power. This paper proposes a transformerless inverter topology with a wide-range power factor operation. Simulation results and extensive experimental results, focused mainly on ground leakage current analysis, showed the effectiveness of the proposed solution.

Transformerless Grid-Connected Converter for PV Plants with Constant Common Mode Voltage and Arbitrary Power Factor / Barater, D.; Buticchi, G.; Lorenzani, Emilio; Malori, V.. - ELETTRONICO. - (2012), pp. 5756-5761. (Intervento presentato al convegno 38th Annual Conference on IEEE Industrial Electronics Society, IECON 2012 tenutosi a Montreal, QC, can nel 25-28 October 2012) [10.1109/IECON.2012.6389044].

Transformerless Grid-Connected Converter for PV Plants with Constant Common Mode Voltage and Arbitrary Power Factor

D. Barater;LORENZANI, EMILIO;
2012

Abstract

Many transformerless topologies for photovoltaic systems were proposed in order to minimize power losses and avoid high levels of ground leakage current (that can arise in such systems). The most efficient PWM strategies achieve this goal by decoupling the grid from the DC Link during the freewheeling phases of the output current. These strategies usually operate only with a unity power factor. However, as solar inverters have penetrated into power distribution networks, new issues have arisen and modifications of regulations governing grid connection of distributed systems were introduced in some countries. One of the new requirements for the inverters connected to the low-voltage grids is the possibility to provide reactive power. This paper proposes a transformerless inverter topology with a wide-range power factor operation. Simulation results and extensive experimental results, focused mainly on ground leakage current analysis, showed the effectiveness of the proposed solution.
2012
38th Annual Conference on IEEE Industrial Electronics Society, IECON 2012
Montreal, QC, can
25-28 October 2012
5756
5761
Barater, D.; Buticchi, G.; Lorenzani, Emilio; Malori, V.
Transformerless Grid-Connected Converter for PV Plants with Constant Common Mode Voltage and Arbitrary Power Factor / Barater, D.; Buticchi, G.; Lorenzani, Emilio; Malori, V.. - ELETTRONICO. - (2012), pp. 5756-5761. (Intervento presentato al convegno 38th Annual Conference on IEEE Industrial Electronics Society, IECON 2012 tenutosi a Montreal, QC, can nel 25-28 October 2012) [10.1109/IECON.2012.6389044].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/839092
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact