We present results on the measurements of the spark probability with CO2 and CF4/CO2 (80/20) mixture, at atmospheric pressure, using 1.5 mm gas gap parallel plate chambers, working at a gas gain ranging from 4.5 x 10(2) to 3.3 x 10(4).
Measurement of the spark probability in single gap parallel plate chambers / A., A., G. L., B., Bizzeti, A., E., C., C., C., F., D., R., D., A., F., M. C., F., V., G., A., K., A., I., V., I., M. I., J., A., M., M., M., S., M., V., P., J. M., S.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 368:(1996), pp. 553-555. [10.1016/0168-9002(95)00864-0]
Measurement of the spark probability in single gap parallel plate chambers
BIZZETI, Andrea;
1996
Abstract
We present results on the measurements of the spark probability with CO2 and CF4/CO2 (80/20) mixture, at atmospheric pressure, using 1.5 mm gas gap parallel plate chambers, working at a gas gain ranging from 4.5 x 10(2) to 3.3 x 10(4).Pubblicazioni consigliate