In this paper a modeling approach to performance evaluation of a shared buffer switching element is described, based on the well-known fluid model of producers and consumers (PC fluid model). A procedure is outlined that leads to a suitable characterization of some typical parameters of the producer and consumer fluid model, making it representative of the shared buffer switch. Simulation analysis is used to investigate the relationships between the behavior of the shared buffer switching element and of the PC fluid model. In the paper it is shown that by means of a suitable fitting of one parameter characterizing the PC fluid model, it is possible to make it representative of the shared buffer in the region of interest for ATM applications. This in spite of the actual operating differences between the real system and the PC fluid model. Numerical results regarding cell loss probability performance and dimensioning of 4 by 4 and 8 by 8 switches are presented and suitably discussed.
Analysis of an ATM Shared Buffer Switch Loaded with Bursty Traffic / F., Callegati; Casoni, Maurizio; G., Corazza; C., Raffaelli. - STAMPA. - 2917:(1996), pp. 410-412. (Intervento presentato al convegno Broadband Access Systems tenutosi a Boston (USA) nel 22 Novembre 1996).
Analysis of an ATM Shared Buffer Switch Loaded with Bursty Traffic
CASONI, Maurizio;
1996
Abstract
In this paper a modeling approach to performance evaluation of a shared buffer switching element is described, based on the well-known fluid model of producers and consumers (PC fluid model). A procedure is outlined that leads to a suitable characterization of some typical parameters of the producer and consumer fluid model, making it representative of the shared buffer switch. Simulation analysis is used to investigate the relationships between the behavior of the shared buffer switching element and of the PC fluid model. In the paper it is shown that by means of a suitable fitting of one parameter characterizing the PC fluid model, it is possible to make it representative of the shared buffer in the region of interest for ATM applications. This in spite of the actual operating differences between the real system and the PC fluid model. Numerical results regarding cell loss probability performance and dimensioning of 4 by 4 and 8 by 8 switches are presented and suitably discussed.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris