In this paper a modeling approach to performance evaluation of a shared buffer switching element is described, based on the well-known fluid model of producers and consumers (PC fluid model). A procedure is outlined that leads to a suitable characterization of some typical parameters of the producer and consumer fluid model, making it representative of the shared buffer switch. Simulation analysis is used to investigate the relationships between the behavior of the shared buffer switching element and of the PC fluid model. In the paper it is shown that by means of a suitable fitting of one parameter characterizing the PC fluid model, it is possible to make it representative of the shared buffer in the region of interest for ATM applications. This in spite of the actual operating differences between the real system and the PC fluid model. Numerical results regarding cell loss probability performance and dimensioning of 4 by 4 and 8 by 8 switches are presented and suitably discussed.

Analysis of an ATM Shared Buffer Switch Loaded with Bursty Traffic / F., Callegati; Casoni, Maurizio; G., Corazza; C., Raffaelli. - STAMPA. - 2917:(1996), pp. 410-412. (Intervento presentato al convegno Broadband Access Systems tenutosi a Boston (USA) nel 22 Novembre 1996).

Analysis of an ATM Shared Buffer Switch Loaded with Bursty Traffic

CASONI, Maurizio;
1996

Abstract

In this paper a modeling approach to performance evaluation of a shared buffer switching element is described, based on the well-known fluid model of producers and consumers (PC fluid model). A procedure is outlined that leads to a suitable characterization of some typical parameters of the producer and consumer fluid model, making it representative of the shared buffer switch. Simulation analysis is used to investigate the relationships between the behavior of the shared buffer switching element and of the PC fluid model. In the paper it is shown that by means of a suitable fitting of one parameter characterizing the PC fluid model, it is possible to make it representative of the shared buffer in the region of interest for ATM applications. This in spite of the actual operating differences between the real system and the PC fluid model. Numerical results regarding cell loss probability performance and dimensioning of 4 by 4 and 8 by 8 switches are presented and suitably discussed.
1996
Broadband Access Systems
Boston (USA)
22 Novembre 1996
2917
410
412
F., Callegati; Casoni, Maurizio; G., Corazza; C., Raffaelli
Analysis of an ATM Shared Buffer Switch Loaded with Bursty Traffic / F., Callegati; Casoni, Maurizio; G., Corazza; C., Raffaelli. - STAMPA. - 2917:(1996), pp. 410-412. (Intervento presentato al convegno Broadband Access Systems tenutosi a Boston (USA) nel 22 Novembre 1996).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/742281
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 2
social impact