Objective: The aim of this study is to evaluate in vivo performance of cobalt-chromium/ceramic fixed partial dentures (FPDs) fabricated using CAD/CAM laser-sintering technology. The purpose is to assess technical and biological outcome compared to traditional cast metal-ceramic FPDs.Method: This retrospective study is conducted in a dental clinic that utilizes the Direct Metal Laser-Sintering (DMLS) CAD/CAM technique to fabricate metal-ceramic FPD since 4 years. The evaluation was taken during the periodical hygiene recall and follow-up.The FPDs were categorized in: 1) Single Dental Crown (1 dental unit) 2)Small Bridges (1-3 units) 3)Wide Bridges ( >3 units). An Evaluation Form was completed, using USPHS criteria to estimate quality and conditions of FPDs: Framework fracture, Veneering Fracture, Occlusal Wear, Marginal Adaptation, Anatomical Form (Alfa (A) to Delta (D) scale).A soft tissue and abutment analysis were also conducted to assess: Plaque Index (PLI), Bleeding on Probing (BoP), Gingival Recession (REC). Moreover the satisfaction of every patient was measured with a Visual Analogue Scale (VAS) with 10 levels.Result: This study is actually in progress. 35 patients with a total of 145 fixed dental prosthetic units were examined until now. The mean observation period is 14,7 ± 10,6 months (maximum: 44 months; minimum: 1 month). There were no framework fracture. 4 patients present 'veneering failures''. Three of these patients are affected by bruxism and parafunctional habits. 1 'wide bridge' (4 dental units) failed as a result of extraction after endodontic disease. The success rate is now 97,14%. The satisfaction rate is: 9,1 ±1,12.Conclusion: Within the limitations of these preliminary results, DMLS FPDs are promising. Success rate is comparable to that found for cast metal-ceramic dental prostheses. Longer observation period and more dental units examination are required to validate these results.

In Vivo Performance Of DMLS Co-Cr FPDs: 1 Year Follow-up / Natali, Alfredo; Bortolini, Sergio; Berzaghi, Andrea; Benatti, D; Ucar, Y.. - In: JOURNAL OF DENTAL RESEARCH. - ISSN 0022-0345. - STAMPA. - 91:(2012), pp. 58-58. (Intervento presentato al convegno IADR 90th General Session, Foz do Iguassù, Brasil - June 20-23, 2012 tenutosi a Foz do Iguassù, Brasil nel 20-23 JUNE 2012).

In Vivo Performance Of DMLS Co-Cr FPDs: 1 Year Follow-up.

NATALI, Alfredo;BORTOLINI, Sergio;BERZAGHI, Andrea;
2012

Abstract

Objective: The aim of this study is to evaluate in vivo performance of cobalt-chromium/ceramic fixed partial dentures (FPDs) fabricated using CAD/CAM laser-sintering technology. The purpose is to assess technical and biological outcome compared to traditional cast metal-ceramic FPDs.Method: This retrospective study is conducted in a dental clinic that utilizes the Direct Metal Laser-Sintering (DMLS) CAD/CAM technique to fabricate metal-ceramic FPD since 4 years. The evaluation was taken during the periodical hygiene recall and follow-up.The FPDs were categorized in: 1) Single Dental Crown (1 dental unit) 2)Small Bridges (1-3 units) 3)Wide Bridges ( >3 units). An Evaluation Form was completed, using USPHS criteria to estimate quality and conditions of FPDs: Framework fracture, Veneering Fracture, Occlusal Wear, Marginal Adaptation, Anatomical Form (Alfa (A) to Delta (D) scale).A soft tissue and abutment analysis were also conducted to assess: Plaque Index (PLI), Bleeding on Probing (BoP), Gingival Recession (REC). Moreover the satisfaction of every patient was measured with a Visual Analogue Scale (VAS) with 10 levels.Result: This study is actually in progress. 35 patients with a total of 145 fixed dental prosthetic units were examined until now. The mean observation period is 14,7 ± 10,6 months (maximum: 44 months; minimum: 1 month). There were no framework fracture. 4 patients present 'veneering failures''. Three of these patients are affected by bruxism and parafunctional habits. 1 'wide bridge' (4 dental units) failed as a result of extraction after endodontic disease. The success rate is now 97,14%. The satisfaction rate is: 9,1 ±1,12.Conclusion: Within the limitations of these preliminary results, DMLS FPDs are promising. Success rate is comparable to that found for cast metal-ceramic dental prostheses. Longer observation period and more dental units examination are required to validate these results.
2012
91
58
58
Natali, Alfredo; Bortolini, Sergio; Berzaghi, Andrea; Benatti, D; Ucar, Y.
In Vivo Performance Of DMLS Co-Cr FPDs: 1 Year Follow-up / Natali, Alfredo; Bortolini, Sergio; Berzaghi, Andrea; Benatti, D; Ucar, Y.. - In: JOURNAL OF DENTAL RESEARCH. - ISSN 0022-0345. - STAMPA. - 91:(2012), pp. 58-58. (Intervento presentato al convegno IADR 90th General Session, Foz do Iguassù, Brasil - June 20-23, 2012 tenutosi a Foz do Iguassù, Brasil nel 20-23 JUNE 2012).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/740355
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact