This paper deals with the experimental problems related to the reconstruction of the position and orientation of the lower limb bones in space during the execution of locomotion and physical exercises. The inaccuracies associated with the relative movement between markers and underlying bone are analysed. Quantitative information regarding this movement was collected by making experiments on subjects who had suffered fractures and were wearing either femoral or tibial external fixators. These latter devices provided frames that were reliably rigid with the bone involved, and hence the possibility of assessing the relative movement between markers mounted on the skin and this bone. Anatomical frames associated with thigh and shank were reconstructed using technical frames based on different clusters of skin markers and their rotation with respect to the relevant bone evaluated. Marker movement was also assessed in subjects with intact musculoskeletal structures using digital videofluoroscopy.
Position and orientation in space of bones during movement: experimental artefacts / A., Cappozzo; Catani, Fabio; A., Leardini; M. G., Benedetti; U. D., Croce. - In: CLINICAL BIOMECHANICS. - ISSN 0268-0033. - ELETTRONICO. - 11:(1996), pp. 90-100.
Position and orientation in space of bones during movement: experimental artefacts.
CATANI, Fabio;
1996
Abstract
This paper deals with the experimental problems related to the reconstruction of the position and orientation of the lower limb bones in space during the execution of locomotion and physical exercises. The inaccuracies associated with the relative movement between markers and underlying bone are analysed. Quantitative information regarding this movement was collected by making experiments on subjects who had suffered fractures and were wearing either femoral or tibial external fixators. These latter devices provided frames that were reliably rigid with the bone involved, and hence the possibility of assessing the relative movement between markers mounted on the skin and this bone. Anatomical frames associated with thigh and shank were reconstructed using technical frames based on different clusters of skin markers and their rotation with respect to the relevant bone evaluated. Marker movement was also assessed in subjects with intact musculoskeletal structures using digital videofluoroscopy.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris