The enantioseparation of reboxetine by HPLC was investigated using chiral stationary phases (CSPs) containingcellulose Tris(3,5-dimethylphenyl)carbamate on silica gel (Chiralcel OD column) as the chiralselector. Reversed phase HPLC was the technique of choice for the analytical enantioseparation of reboxetine,while the chiral semipreparative separation was obtained with the same CSP, but in normal phaseconditions. The effects of the mobile phase pH and composition on analytical retention, enantioselectivityand resolution were investigated. The best performance was obtained using a mobile phase composed of0.5Msodium perchlorate at pH 6 and acetonitrile in the 60/40 (v/v) ratio. The semipreparative separationhas allowed obtaining pure enantiomers, but required the preparation of reboxetine free base. Differentn-hexane/alcohol mixtures were tested as mobile phases, varying both the nature of the alcohol and itspercentage in the mobile phase. Different n-hexane/alcohol mixtures were tested as mobile phase andthe best results were obtained by using a mobile phase composed of n-hexane and 2-propanol (80:20,v/v).
Enantioseparation of the antidepressant reboxetine / Cannazza, Giuseppe; Braghiroli, Daniela; Carrozzo, Marina Maria; Parenti, Carlo; Sabbioni, Cesare; Mandrioli, Roberto; Fanali, Salvatore; Raggi, Maria Augusta. - In: JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS. - ISSN 0731-7085. - STAMPA. - 48:3(2008), pp. 991-996. [10.1016/j.jpba.2008.06.026]
Enantioseparation of the antidepressant reboxetine
CANNAZZA, Giuseppe;BRAGHIROLI, Daniela;CARROZZO, Marina Maria;PARENTI, Carlo;
2008
Abstract
The enantioseparation of reboxetine by HPLC was investigated using chiral stationary phases (CSPs) containingcellulose Tris(3,5-dimethylphenyl)carbamate on silica gel (Chiralcel OD column) as the chiralselector. Reversed phase HPLC was the technique of choice for the analytical enantioseparation of reboxetine,while the chiral semipreparative separation was obtained with the same CSP, but in normal phaseconditions. The effects of the mobile phase pH and composition on analytical retention, enantioselectivityand resolution were investigated. The best performance was obtained using a mobile phase composed of0.5Msodium perchlorate at pH 6 and acetonitrile in the 60/40 (v/v) ratio. The semipreparative separationhas allowed obtaining pure enantiomers, but required the preparation of reboxetine free base. Differentn-hexane/alcohol mixtures were tested as mobile phases, varying both the nature of the alcohol and itspercentage in the mobile phase. Different n-hexane/alcohol mixtures were tested as mobile phase andthe best results were obtained by using a mobile phase composed of n-hexane and 2-propanol (80:20,v/v).File | Dimensione | Formato | |
---|---|---|---|
Enantioseparation of the antidepressant reboxetine.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
352.39 kB
Formato
Adobe PDF
|
352.39 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris