PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS.

Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model / R., Autorino; F. J., Kim; A., Rane; M., De Sio; R. J., Stein; R., Damiano; Micali, Salvatore; J., Correia Pinto; J. H., Kaouk; E., Lima. - In: JOURNAL OF ENDOUROLOGY. - ISSN 0892-7790. - ELETTRONICO. - 25(3):(2011), pp. 419-424. [10.1089/end.2010.0415]

Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

MICALI, Salvatore;
2011

Abstract

PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS.
2011
25(3)
419
424
Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model / R., Autorino; F. J., Kim; A., Rane; M., De Sio; R. J., Stein; R., Damiano; Micali, Salvatore; J., Correia Pinto; J. H., Kaouk; E., Lima. - In: JOURNAL OF ENDOUROLOGY. - ISSN 0892-7790. - ELETTRONICO. - 25(3):(2011), pp. 419-424. [10.1089/end.2010.0415]
R., Autorino; F. J., Kim; A., Rane; M., De Sio; R. J., Stein; R., Damiano; Micali, Salvatore; J., Correia Pinto; J. H., Kaouk; E., Lima
File in questo prodotto:
File Dimensione Formato  
76 - end.2010.0415.pdf

Accesso riservato

Tipologia: Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione 273.98 kB
Formato Adobe PDF
273.98 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/709398
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact