To evaluate the effects of physiological ventilatory patterns on P(a-ET)CO2 gradient and on the alveolar dead space production during controlled mechanical ventilation.Prospective and experimental comparison among three different ventilatory settings in three different groups of subjects.General surgery's operating-theatre in university hospital.Twenty-eight patients subdivided randomly in 3 groups differing for ventilatory setting. I group: constant tidal volume (VC = 8 ml.kg-1) and 3 different respiratory frequencies (f = 10, 12 and 14 breaths.min-1); II group: constant ventilation (112 ml.kg-1) but VC and f modified in three different ways; III group: inspiratory volume was set to give an end-tidal PCO2 (PETCO2) of about 35 mmHg. The cases were subdivided, on the basis of P(a-ET)CO2 distribution, in three groups: group with values larger than mean plus 1 standard deviation, group with values between +/- 1 standard deviation and group with values lower than mean minus 1 standard deviation. Moreover in two homogeneous groups for age.General surgery but not important because measures were performed before surgical manoeuvres.Anthropometrical data (age and body weight), PaCO2, PETCO2, heart rate, invasive arterial pressure, ventilatory parameters and airway pressure were collected for every subject and ventilatory setting; arterial to end-tidal difference P(a-ET)CO2 and P(a-ET)CO2.PaCO2(-1) were calculated during data analysis. The P(a-ETFCO2 and P(a-ET)CO2.PaCO2(-1) values were not significantly different among the three different ventilatory patterns both in the first and in the second group. P(a-ET)CO2 values were significantly correlated with age, body weight and airway pressure. These parameters were correlated significantly also with P(a-ET)CO2.PaCO2(-1) values.Ventilatory setting, used in a normal physiological range, don't affect P(a-ET)CO2 difference during mechanical ventilation. Age, body weight and airway pressure of the patient must be considered to obtain a correct value of PaCO2 by the measure of PETCO2.

[Effects of age, body weight, and ventilatory pattern on the difference between arterial and end-tidal PCO2] / F., Colò; Girardis, Massimo; A., Pasqualucci; U. D., Broi; A., Pasetto. - In: MINERVA ANESTESIOLOGICA. - ISSN 0375-9393. - STAMPA. - 60:(1994), pp. 367-374.

[Effects of age, body weight, and ventilatory pattern on the difference between arterial and end-tidal PCO2].

GIRARDIS, Massimo;
1994

Abstract

To evaluate the effects of physiological ventilatory patterns on P(a-ET)CO2 gradient and on the alveolar dead space production during controlled mechanical ventilation.Prospective and experimental comparison among three different ventilatory settings in three different groups of subjects.General surgery's operating-theatre in university hospital.Twenty-eight patients subdivided randomly in 3 groups differing for ventilatory setting. I group: constant tidal volume (VC = 8 ml.kg-1) and 3 different respiratory frequencies (f = 10, 12 and 14 breaths.min-1); II group: constant ventilation (112 ml.kg-1) but VC and f modified in three different ways; III group: inspiratory volume was set to give an end-tidal PCO2 (PETCO2) of about 35 mmHg. The cases were subdivided, on the basis of P(a-ET)CO2 distribution, in three groups: group with values larger than mean plus 1 standard deviation, group with values between +/- 1 standard deviation and group with values lower than mean minus 1 standard deviation. Moreover in two homogeneous groups for age.General surgery but not important because measures were performed before surgical manoeuvres.Anthropometrical data (age and body weight), PaCO2, PETCO2, heart rate, invasive arterial pressure, ventilatory parameters and airway pressure were collected for every subject and ventilatory setting; arterial to end-tidal difference P(a-ET)CO2 and P(a-ET)CO2.PaCO2(-1) were calculated during data analysis. The P(a-ETFCO2 and P(a-ET)CO2.PaCO2(-1) values were not significantly different among the three different ventilatory patterns both in the first and in the second group. P(a-ET)CO2 values were significantly correlated with age, body weight and airway pressure. These parameters were correlated significantly also with P(a-ET)CO2.PaCO2(-1) values.Ventilatory setting, used in a normal physiological range, don't affect P(a-ET)CO2 difference during mechanical ventilation. Age, body weight and airway pressure of the patient must be considered to obtain a correct value of PaCO2 by the measure of PETCO2.
1994
60
367
374
[Effects of age, body weight, and ventilatory pattern on the difference between arterial and end-tidal PCO2] / F., Colò; Girardis, Massimo; A., Pasqualucci; U. D., Broi; A., Pasetto. - In: MINERVA ANESTESIOLOGICA. - ISSN 0375-9393. - STAMPA. - 60:(1994), pp. 367-374.
F., Colò; Girardis, Massimo; A., Pasqualucci; U. D., Broi; A., Pasetto
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/703818
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact