A double layered hydroxide anionic clay containing chloride or nitrate as the interlayer anion has been used to prepare ion-selective electrodes (ISE) for potentiometric sensing of the intercalated anionic species. The electrodes exhibited a linear range for the potential response to logarithm of concentration: from 5.0 x 10(-5) to 2.0 x 10(-1) M with an average slope equal to - 54.2 mV decade(-1) for chloride and from 2.0 x 10(-4) to 1.0 M with an average slope equal to - 48.3 mV decade-1 for nitrate. The response time was from 1 to 6 min, depending on the analyte concentration; the stability of the signal was quite satisfactory. The effect of interfering ions has been investigated and the values of the relevant selectivity constants have been determined. The lifetime of the sensors was at least 2 weeks. (C) 2000 Elsevier Science B.V. All rights reserved.

Hydrotalcite-like compounds as ionophores for the development of anion potentiometric sensors / Ballarin, B; Morigi, M; Scavetta, E; Seeber, Renato; Tonelli, D.. - In: JOURNAL OF ELECTROANALYTICAL CHEMISTRY. - ISSN 1572-6657. - STAMPA. - 492:1(2000), pp. 7-14. [10.1016/S0022-0728(00)00212-6]

Hydrotalcite-like compounds as ionophores for the development of anion potentiometric sensors

SEEBER, Renato;
2000

Abstract

A double layered hydroxide anionic clay containing chloride or nitrate as the interlayer anion has been used to prepare ion-selective electrodes (ISE) for potentiometric sensing of the intercalated anionic species. The electrodes exhibited a linear range for the potential response to logarithm of concentration: from 5.0 x 10(-5) to 2.0 x 10(-1) M with an average slope equal to - 54.2 mV decade(-1) for chloride and from 2.0 x 10(-4) to 1.0 M with an average slope equal to - 48.3 mV decade-1 for nitrate. The response time was from 1 to 6 min, depending on the analyte concentration; the stability of the signal was quite satisfactory. The effect of interfering ions has been investigated and the values of the relevant selectivity constants have been determined. The lifetime of the sensors was at least 2 weeks. (C) 2000 Elsevier Science B.V. All rights reserved.
2000
492
1
7
14
Hydrotalcite-like compounds as ionophores for the development of anion potentiometric sensors / Ballarin, B; Morigi, M; Scavetta, E; Seeber, Renato; Tonelli, D.. - In: JOURNAL OF ELECTROANALYTICAL CHEMISTRY. - ISSN 1572-6657. - STAMPA. - 492:1(2000), pp. 7-14. [10.1016/S0022-0728(00)00212-6]
Ballarin, B; Morigi, M; Scavetta, E; Seeber, Renato; Tonelli, D.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/6846
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 38
social impact