Non-linear loads and grid connected converters, whose utilization is constantly growing, have been causing problems regarding the power quality. These problems comprehend the generation of harmonics in the current provided by the power distributor. Among different kinds of deterioration, there is the issue of the DC current component. As a matter of fact, a DC current is detrimental for the distribution power transformer, as it leads to saturation the magnetic core. The saturation of the power transformer increases the VAR absorption, leading to possible damage the magnetic component due to overheating. This paper proposes a compensator system based on a non linear sensor that acts as an active filter for the DC current component flowing in the power lines. The paper is organized as follows: the first part outlines the strategy, then the stability issue is addressed by means of a simplified model. A simulation verification showed that the simplified model closely approximates the real system.

A Nonlinear Reactor for DC Current Compensation in Single Phase Power Lines / G., Buticchi; L., Consolini; Lorenzani, Emilio. - ELETTRONICO. - 44:1(2011), pp. 12273-12278. (Intervento presentato al convegno 18th IFAC World Congress, 2011 tenutosi a Milano, Italy nel 28 August-2 September 2011) [10.3182/20110828-6-IT-1002.03511].

A Nonlinear Reactor for DC Current Compensation in Single Phase Power Lines

LORENZANI, EMILIO
2011

Abstract

Non-linear loads and grid connected converters, whose utilization is constantly growing, have been causing problems regarding the power quality. These problems comprehend the generation of harmonics in the current provided by the power distributor. Among different kinds of deterioration, there is the issue of the DC current component. As a matter of fact, a DC current is detrimental for the distribution power transformer, as it leads to saturation the magnetic core. The saturation of the power transformer increases the VAR absorption, leading to possible damage the magnetic component due to overheating. This paper proposes a compensator system based on a non linear sensor that acts as an active filter for the DC current component flowing in the power lines. The paper is organized as follows: the first part outlines the strategy, then the stability issue is addressed by means of a simplified model. A simulation verification showed that the simplified model closely approximates the real system.
2011
18th IFAC World Congress, 2011
Milano, Italy
28 August-2 September 2011
44
12273
12278
G., Buticchi; L., Consolini; Lorenzani, Emilio
A Nonlinear Reactor for DC Current Compensation in Single Phase Power Lines / G., Buticchi; L., Consolini; Lorenzani, Emilio. - ELETTRONICO. - 44:1(2011), pp. 12273-12278. (Intervento presentato al convegno 18th IFAC World Congress, 2011 tenutosi a Milano, Italy nel 28 August-2 September 2011) [10.3182/20110828-6-IT-1002.03511].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/684329
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact