A line frequency transformer is usually employed in grid-connected power converters, from both renewable and traditional energy sources, in order to suppress the DC current component and the ground leakage current. Solutions employing a high frequency transformer or employing no transformer at all have recently been investigated in order to reduce size, weight and cost. As a consequence, unless a suitable remedy is adopted, a DC current component exceeding the limits enforced by international standards may be injected into the grid.This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in the case of a full-bridge, single-phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the current transducer.The simulation results have confirmed the theoretical behavior of the proposed solution, while the experimental ones, performed for different values of output power and for different current control architectures, have shown its effectiveness.
A DC Offset Current Compensation Strategy in Transformerless Grid-Connected Power Converters / Buticchi, G.; Lorenzani, Emilio; Franceschini, G.. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - STAMPA. - 26:4(2011), pp. 2743-2751. [10.1109/TPWRD.2011.2167160]
A DC Offset Current Compensation Strategy in Transformerless Grid-Connected Power Converters
LORENZANI, EMILIO;G. Franceschini
2011
Abstract
A line frequency transformer is usually employed in grid-connected power converters, from both renewable and traditional energy sources, in order to suppress the DC current component and the ground leakage current. Solutions employing a high frequency transformer or employing no transformer at all have recently been investigated in order to reduce size, weight and cost. As a consequence, unless a suitable remedy is adopted, a DC current component exceeding the limits enforced by international standards may be injected into the grid.This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in the case of a full-bridge, single-phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the current transducer.The simulation results have confirmed the theoretical behavior of the proposed solution, while the experimental ones, performed for different values of output power and for different current control architectures, have shown its effectiveness.File | Dimensione | Formato | |
---|---|---|---|
A DC Offset Current Compensation Strategy.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
1.74 MB
Formato
Adobe PDF
|
1.74 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris