A stopped-flow bidimensional recycle HPLC (sf-BD-rHPLC) configuration has been used to investigate simultaneously the stereo and chemical stability of labile chiral compounds. The single enantiomers of a racemate can be separated on chiral column (first dimension) and each one can be trapped in the achiral column (second dimension) that works as reactor.By filling the achiral column with the appropriate aqueous buffers it is possible to evaluate the stability of the trapped enantiomer toward aqueous buffer itself. It was possible to recycle the reaction products formed in the chiral column (first dimension) where they are separated by a second six valve port. The reaction rate constants were calculated for the different processes occurred in the achiral column by means of corresponding peak areas. The method was applied to a pharmacological active compound: (±)7-chloro-5-ethyl-3-methyl-3,4-dihydro-2H-benzo[1,2,4]thiadiazine 1,1-dioxide ((±)-1) to evaluate enantiostability and hydrolysis in conditions similar to those of biological fluid. A classical batchwise kinetic method was used to calculate rate constants of hydrolysis and enantiomerization at the same temperature and in the same solvents used in sf-BD-rHPLC. The good agreement of the results obtained validate the novel procedure developed. Furthermore, the results generated off-line were used to determine the influence of solvents on the racemization of (±)-1.

Evaluation of stereo and chemical stability of chiral compounds / Cannazza, Giuseppe; Battisti, UMBERTO MARIA; Carrozzo, Marina Maria; Brasili, Livio; Braghiroli, Daniela; Parenti, Carlo. - In: CHIRALITY. - ISSN 0899-0042. - STAMPA. - 23:10(2011), pp. 851-859. [10.1002/chir.20941]

Evaluation of stereo and chemical stability of chiral compounds

CANNAZZA, Giuseppe;BATTISTI, UMBERTO MARIA;CARROZZO, Marina Maria;BRASILI, Livio;BRAGHIROLI, Daniela;PARENTI, Carlo
2011

Abstract

A stopped-flow bidimensional recycle HPLC (sf-BD-rHPLC) configuration has been used to investigate simultaneously the stereo and chemical stability of labile chiral compounds. The single enantiomers of a racemate can be separated on chiral column (first dimension) and each one can be trapped in the achiral column (second dimension) that works as reactor.By filling the achiral column with the appropriate aqueous buffers it is possible to evaluate the stability of the trapped enantiomer toward aqueous buffer itself. It was possible to recycle the reaction products formed in the chiral column (first dimension) where they are separated by a second six valve port. The reaction rate constants were calculated for the different processes occurred in the achiral column by means of corresponding peak areas. The method was applied to a pharmacological active compound: (±)7-chloro-5-ethyl-3-methyl-3,4-dihydro-2H-benzo[1,2,4]thiadiazine 1,1-dioxide ((±)-1) to evaluate enantiostability and hydrolysis in conditions similar to those of biological fluid. A classical batchwise kinetic method was used to calculate rate constants of hydrolysis and enantiomerization at the same temperature and in the same solvents used in sf-BD-rHPLC. The good agreement of the results obtained validate the novel procedure developed. Furthermore, the results generated off-line were used to determine the influence of solvents on the racemization of (±)-1.
2011
23
10
851
859
Evaluation of stereo and chemical stability of chiral compounds / Cannazza, Giuseppe; Battisti, UMBERTO MARIA; Carrozzo, Marina Maria; Brasili, Livio; Braghiroli, Daniela; Parenti, Carlo. - In: CHIRALITY. - ISSN 0899-0042. - STAMPA. - 23:10(2011), pp. 851-859. [10.1002/chir.20941]
Cannazza, Giuseppe; Battisti, UMBERTO MARIA; Carrozzo, Marina Maria; Brasili, Livio; Braghiroli, Daniela; Parenti, Carlo
File in questo prodotto:
File Dimensione Formato  
Evaluation of stereo and chemical stability of chiral compounds.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 375.2 kB
Formato Adobe PDF
375.2 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/684289
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact