In this article are discussed some meaningful issues concerning the measurement of radiated emissions generated by standard and hybrid architectures amplifiers. These measurements aimed to compare different levels of radiated emission for architectures also related to different environments.
Hybrid architectures for EMC mitigation of switching audio amplifier / Bellini, A.; Boccedi, V.; Franceschini, G.; Lorenzani, Emilio; Montanari, I.; Tacchini, A.. - ELETTRONICO. - (2009), pp. 1-4. (Intervento presentato al convegno IEEE EMC Europe 2009 International Symposium on tenutosi a Athens (Greece) nel 2009-june) [10.1109/EMCEUROPE.2009.5189680].
Hybrid architectures for EMC mitigation of switching audio amplifier
G. Franceschini;LORENZANI, EMILIO;
2009
Abstract
In this article are discussed some meaningful issues concerning the measurement of radiated emissions generated by standard and hybrid architectures amplifiers. These measurements aimed to compare different levels of radiated emission for architectures also related to different environments.Pubblicazioni consigliate