This paper proposes a saturation compensation strategy for single phase grid-connected power converters based on line frequency transformer. High power quality operations requires the direct control of injected grid current providing zero steady-state error at grid frequency. A zero steady-state error at grid frequency can be obtained by a control in a synchronous reference frame that ensures an infinite open loop gain at fundamental frequency and a superior disturbance rejection. However, the direct control of grid current is archived providing that transformer core saturation is avoided. Since the transformer blocks out the DC components the feedback loop closed on the transformer output current can lead to core saturation. This paper presents a compensation strategy based only on the monitoring of the output current distortion around voltage zero crossings. The proposed solution is free from offset problems, since no DC measurement is required. Experimental results confirm the effectiveness of the proposed control architecture and of the strategy adopted to avoid transformer core saturation. ©2010 IEEE.

Compensation of magnetic core saturation for grid connected single-phase power converters / Franceschini, G.; Lorenzani, E.; Bellini, A.; Fratta, A.. - ELETTRONICO. - (2010), pp. 1-6. (Intervento presentato al convegno 19th International Conference on Electrical Machines, ICEM 2010 tenutosi a Roma nel 6-8 September 2010) [10.1109/ICELMACH.2010.5607922].

Compensation of magnetic core saturation for grid connected single-phase power converters

G. Franceschini;E. Lorenzani;A. Bellini;
2010

Abstract

This paper proposes a saturation compensation strategy for single phase grid-connected power converters based on line frequency transformer. High power quality operations requires the direct control of injected grid current providing zero steady-state error at grid frequency. A zero steady-state error at grid frequency can be obtained by a control in a synchronous reference frame that ensures an infinite open loop gain at fundamental frequency and a superior disturbance rejection. However, the direct control of grid current is archived providing that transformer core saturation is avoided. Since the transformer blocks out the DC components the feedback loop closed on the transformer output current can lead to core saturation. This paper presents a compensation strategy based only on the monitoring of the output current distortion around voltage zero crossings. The proposed solution is free from offset problems, since no DC measurement is required. Experimental results confirm the effectiveness of the proposed control architecture and of the strategy adopted to avoid transformer core saturation. ©2010 IEEE.
2010
19th International Conference on Electrical Machines, ICEM 2010
Roma
6-8 September 2010
1
6
Franceschini, G.; Lorenzani, E.; Bellini, A.; Fratta, A.
Compensation of magnetic core saturation for grid connected single-phase power converters / Franceschini, G.; Lorenzani, E.; Bellini, A.; Fratta, A.. - ELETTRONICO. - (2010), pp. 1-6. (Intervento presentato al convegno 19th International Conference on Electrical Machines, ICEM 2010 tenutosi a Roma nel 6-8 September 2010) [10.1109/ICELMACH.2010.5607922].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/649594
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact