The effect of disinfectants was determined on the mechanical and chemical resistance of high-density polyethylene pipes, commonly used in modern urban networks for water conveyance. A fully monitored test plant was built that was able to simultaneously expose both pipe sections and pre-cut dumbbell specimens to chlorinated and non-chlorinated water. PE100 polyethylene pipes for alimentary use with a nominal diameter DN 32 were tested in two sets of experiments involving both chlorine dioxide (at a constant concentration of 5 ppm), and sodium hypochlorite (at a constant concentration of 2.5 ppm). The effects of these disinfectants were assessed using monotonic tensile tests on dumbbell specimens and oxidation induction time tests. Pressure tests at a constant temperature were also performed to assess any damage in the pipe samples after one year of exposure to chlorine dioxide. The results from the tensile and oxidation induction time tests showed that chlorine dioxide was the most aggressive disinfectant. Nevertheless, the pressure tests at a constant temperature did not show any failure of the pipes after 2000 h of exposure.
Effect of chlorinated water on the oxidative resistance and the mechanical strength of polyethylene pipes / Castagnetti, Davide; SCIRE' MAMMANO, Giovanni; Dragoni, Eugenio. - In: POLYMER TESTING. - ISSN 0142-9418. - STAMPA. - 30:3(2011), pp. 277-285. [10.1016/j.polymertesting.2010.12.001]
Effect of chlorinated water on the oxidative resistance and the mechanical strength of polyethylene pipes
CASTAGNETTI, Davide;SCIRE' MAMMANO, Giovanni;DRAGONI, Eugenio
2011
Abstract
The effect of disinfectants was determined on the mechanical and chemical resistance of high-density polyethylene pipes, commonly used in modern urban networks for water conveyance. A fully monitored test plant was built that was able to simultaneously expose both pipe sections and pre-cut dumbbell specimens to chlorinated and non-chlorinated water. PE100 polyethylene pipes for alimentary use with a nominal diameter DN 32 were tested in two sets of experiments involving both chlorine dioxide (at a constant concentration of 5 ppm), and sodium hypochlorite (at a constant concentration of 2.5 ppm). The effects of these disinfectants were assessed using monotonic tensile tests on dumbbell specimens and oxidation induction time tests. Pressure tests at a constant temperature were also performed to assess any damage in the pipe samples after one year of exposure to chlorine dioxide. The results from the tensile and oxidation induction time tests showed that chlorine dioxide was the most aggressive disinfectant. Nevertheless, the pressure tests at a constant temperature did not show any failure of the pipes after 2000 h of exposure.File | Dimensione | Formato | |
---|---|---|---|
2009.PT.Castagnetti.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
855.72 kB
Formato
Adobe PDF
|
855.72 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris