To measure blood flow rate in ex-vivo circulation, we propose an optical Doppler flowmeter based on the self-mixing effect within a laser diode (SM-LD). Advantages in adopting SM-LD techniques derive from reduced costs, ease of implementation and limited size. Moreover, the provided contactless sensing allows sensor reuse, hence further cost reduction. Preliminary measurements performed on bovine blood are reported, thus demonstrating the applicability of the proposed measurement method.

Blood flow measurement in extracorporeal circulation using self-mixing laser diode / Cattini, Stefano; Michele, Norgia; Alessandro, Pesatori; Rovati, Luigi. - STAMPA. - 7572:(2010), pp. 75720A-75720A-11. ( SPIE PW: Optical Diagnostics and Sensing X: Toward Point-of-Care Diagnostics San Francisco, CA, usa 8 February 2010) [10.1117/12.840240].

Blood flow measurement in extracorporeal circulation using self-mixing laser diode

CATTINI, Stefano;ROVATI, Luigi
2010

Abstract

To measure blood flow rate in ex-vivo circulation, we propose an optical Doppler flowmeter based on the self-mixing effect within a laser diode (SM-LD). Advantages in adopting SM-LD techniques derive from reduced costs, ease of implementation and limited size. Moreover, the provided contactless sensing allows sensor reuse, hence further cost reduction. Preliminary measurements performed on bovine blood are reported, thus demonstrating the applicability of the proposed measurement method.
2010
no
Inglese
SPIE PW: Optical Diagnostics and Sensing X: Toward Point-of-Care Diagnostics
San Francisco, CA, usa
8 February 2010
Optical Diagnostics and Sensing X: Toward Point-of-Care Diagnostics
7572
75720A
75720A-11
9780819479686
SPIE
STATI UNITI D'AMERICA
1000 20TH ST, PO BOX 10, BELLINGHAM, WA 98227-0010 USA
Internazionale
Contributo
Laser Doppler; Blood flow measurement; Self-mixing
Cattini, Stefano; Michele, Norgia; Alessandro, Pesatori; Rovati, Luigi
Atti di CONVEGNO::Relazione in Atti di Convegno
273
4
Blood flow measurement in extracorporeal circulation using self-mixing laser diode / Cattini, Stefano; Michele, Norgia; Alessandro, Pesatori; Rovati, Luigi. - STAMPA. - 7572:(2010), pp. 75720A-75720A-11. ( SPIE PW: Optical Diagnostics and Sensing X: Toward Point-of-Care Diagnostics San Francisco, CA, usa 8 February 2010) [10.1117/12.840240].
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/647590
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 11
social impact