An experimental analysis is here proposed on water-mistsprays operating at high supply pressure. Advancedlaser-based diagnostics has been employed to performmeasurements. In particular, a Malvern Spraytec devicehas been used to measure drop-size distribution at various distances from the injector outlet along the spray axis. Moreover, initial velocity has been determined through a PIV analysis. Some evaluations of the spraycone angle have been proposed as an additional outcome of the analysis. Different nozzles have beenemployed to produce the water-mist spray and operativepressure has been set at values of interest for fireprotectionapplications, which constitute the reference field for the present work.

Drop-size and initial-velocity measurements in water-mist sprays / Santangelo, Paolo Emilio; Valdiserri, Paolo; Tartarini, Paolo. - STAMPA. - (2009), pp. 131-136. (Intervento presentato al convegno XXVII Congresso Nazionale UIT sulla Trasmissione del Calore tenutosi a Reggio Emilia, Italia nel 22-24 Giugno 2009).

Drop-size and initial-velocity measurements in water-mist sprays

Santangelo, Paolo Emilio;Tartarini, Paolo
2009

Abstract

An experimental analysis is here proposed on water-mistsprays operating at high supply pressure. Advancedlaser-based diagnostics has been employed to performmeasurements. In particular, a Malvern Spraytec devicehas been used to measure drop-size distribution at various distances from the injector outlet along the spray axis. Moreover, initial velocity has been determined through a PIV analysis. Some evaluations of the spraycone angle have been proposed as an additional outcome of the analysis. Different nozzles have beenemployed to produce the water-mist spray and operativepressure has been set at values of interest for fireprotectionapplications, which constitute the reference field for the present work.
2009
XXVII Congresso Nazionale UIT sulla Trasmissione del Calore
Reggio Emilia, Italia
22-24 Giugno 2009
131
136
Santangelo, Paolo Emilio; Valdiserri, Paolo; Tartarini, Paolo
Drop-size and initial-velocity measurements in water-mist sprays / Santangelo, Paolo Emilio; Valdiserri, Paolo; Tartarini, Paolo. - STAMPA. - (2009), pp. 131-136. (Intervento presentato al convegno XXVII Congresso Nazionale UIT sulla Trasmissione del Calore tenutosi a Reggio Emilia, Italia nel 22-24 Giugno 2009).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/618413
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact