This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines.
Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-Non Invasive Multicenter Italian Study for Coronary Artery Disease) / R., Marano; F. D., Cobelli; I., Floriani; C., Becker; C., Herzog; M., Centonze; G., Morana; G. F., Gualdi; Ligabue, Guido; G., Pontone; C., Catalano; D., Chiappino; M., Midiri; G., Simonetti; F., Marchisio; L., Olivetti; R., Fattori; L., Bonomo; A. D., Maschio; N. I., M.. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - ELETTRONICO. - 19:5(2009), pp. 1114-1123. [10.1007/s00330-008-1239-8]
Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-Non Invasive Multicenter Italian Study for Coronary Artery Disease)
LIGABUE, Guido;
2009
Abstract
This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines.File | Dimensione | Formato | |
---|---|---|---|
2009 MARANO european rad 2009.pdf
Accesso riservato
Tipologia:
AAM - Versione dell'autore revisionata e accettata per la pubblicazione
Dimensione
144.53 kB
Formato
Adobe PDF
|
144.53 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris