In order to examine the influence that shape and chemistry of different materials have on the incitement of a tissue reaction, we implanted five materials (the two metals Ni and Co, the two ceramics TiO2 and SiO2, and the polymer poly vinyl-chloride) as nanoparticles or bulk, in the dorsal muscles of 50 rats. After 6 or 12 months, rats were euthanized and the implanted materials were excised together with the surrounding tissue. After a first histological evaluation, the specimens were prepared for environmental scanning electron microscopy (ESEM) and for energy dispersive spectroscopy (EDS), in order to analyse the chemical composition of the implanted material after the biological interaction had occurred, and to evaluate the possible corrosion and diffusion of the materials at tissue interface. The results indicate that the metals at nanoscale size have a carcinogenic effect, while the bulk materials only induce a foreign-body reaction. The ESEM observations show a chemical transformation of the materials. Corrosion of the metals and subsequent recombination of the released ions in a sort of organic-inorganic crystals is showed and verified by the EDS analyses. Finally, our hypotheses of the involved pathological mechanism are suggested.
ESEM evaluations of muscle/nanoparticles interface in a rat model / Gatti, Antonietta; James, Kirkpatrick; Gambarelli, Andrea; Federico, Capitani; Torsten, Hansen; Rosy, Eloy; Gaelle, Clermont. - In: JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE. - ISSN 0957-4530. - STAMPA. - 19:(2008), pp. 1515-1522. [10.1007/s10856-008-3385-6]
ESEM evaluations of muscle/nanoparticles interface in a rat model
GATTI, Antonietta;GAMBARELLI, Andrea;
2008
Abstract
In order to examine the influence that shape and chemistry of different materials have on the incitement of a tissue reaction, we implanted five materials (the two metals Ni and Co, the two ceramics TiO2 and SiO2, and the polymer poly vinyl-chloride) as nanoparticles or bulk, in the dorsal muscles of 50 rats. After 6 or 12 months, rats were euthanized and the implanted materials were excised together with the surrounding tissue. After a first histological evaluation, the specimens were prepared for environmental scanning electron microscopy (ESEM) and for energy dispersive spectroscopy (EDS), in order to analyse the chemical composition of the implanted material after the biological interaction had occurred, and to evaluate the possible corrosion and diffusion of the materials at tissue interface. The results indicate that the metals at nanoscale size have a carcinogenic effect, while the bulk materials only induce a foreign-body reaction. The ESEM observations show a chemical transformation of the materials. Corrosion of the metals and subsequent recombination of the released ions in a sort of organic-inorganic crystals is showed and verified by the EDS analyses. Finally, our hypotheses of the involved pathological mechanism are suggested.File | Dimensione | Formato | |
---|---|---|---|
ESEM evaluations of muscle nanoparticles interface.pdf
Accesso riservato
Tipologia:
Versione pubblicata dall'editore
Dimensione
623.1 kB
Formato
Adobe PDF
|
623.1 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris