Polyethylene pipes for water conveyance may present sensitivity to disinfectants employed to assure water potability. In particular, chlorine based disinfectants could affect their structural properties, which are mainly assessed through monotonic tensile test. A systematic experimental plan, performed to investigate the effects of chlorine based disinfectant on the mechanical properties of PE pipes, emphasized the high variability of the measured parameters, in particular with regard to percentage elongation at fracture. A research aimed at identifying whichfactors affect the outcome of the monotonic tensile test, and which combination of such factors provides a robust setup of the experimental procedure, is presented here. A systematic approach has been adopted considering a fullfactorial experimental plan, and varying each factor between two levels. From the outcome of the experimental results the influence of the test speed, the cutting die, the cutting direction and the pipe diameter has been assessed.

Robust set up of experimental procedure for monotonic tensile test on polyethylene specimens / Castagnetti, Davide; Dragoni, Eugenio; SCIRE' MAMMANO, Giovanni. - STAMPA. - 1:(2007), pp. 189-192. (Intervento presentato al convegno 6th Youth Symposium on Experimental Solid Mechanics tenutosi a Vrnjacka Banja - Serbia nel 09 - 12 Maggio 2007).

Robust set up of experimental procedure for monotonic tensile test on polyethylene specimens

CASTAGNETTI, Davide;DRAGONI, Eugenio;SCIRE' MAMMANO, Giovanni
2007

Abstract

Polyethylene pipes for water conveyance may present sensitivity to disinfectants employed to assure water potability. In particular, chlorine based disinfectants could affect their structural properties, which are mainly assessed through monotonic tensile test. A systematic experimental plan, performed to investigate the effects of chlorine based disinfectant on the mechanical properties of PE pipes, emphasized the high variability of the measured parameters, in particular with regard to percentage elongation at fracture. A research aimed at identifying whichfactors affect the outcome of the monotonic tensile test, and which combination of such factors provides a robust setup of the experimental procedure, is presented here. A systematic approach has been adopted considering a fullfactorial experimental plan, and varying each factor between two levels. From the outcome of the experimental results the influence of the test speed, the cutting die, the cutting direction and the pipe diameter has been assessed.
2007
6th Youth Symposium on Experimental Solid Mechanics
Vrnjacka Banja - Serbia
09 - 12 Maggio 2007
1
189
192
Castagnetti, Davide; Dragoni, Eugenio; SCIRE' MAMMANO, Giovanni
Robust set up of experimental procedure for monotonic tensile test on polyethylene specimens / Castagnetti, Davide; Dragoni, Eugenio; SCIRE' MAMMANO, Giovanni. - STAMPA. - 1:(2007), pp. 189-192. (Intervento presentato al convegno 6th Youth Symposium on Experimental Solid Mechanics tenutosi a Vrnjacka Banja - Serbia nel 09 - 12 Maggio 2007).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/587405
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact