The response of the human eye to flicker depends on the type of lamp used. Standard flickermeters measure the voltage across the lamp and assumes a 60-W incandescent lamp as a light source. When a different lamp is the light flicker source, standard flickermeters give erroneous results. This paper presents a dynamic model of the eye-brain response to flicker. The model is based on the analysis of the light emitted by the lamp. A suitable measurement system has been developed, and three different kinds of lamps have been considered. Experimental results show how the emitted light spectra and the human eye response to different colors combined to determine the level of annoyance. The uncertainty affecting such results, which arises from the hardware of the developed system, has been also estimated.

A Measurement System for the Analysis of the Response of the Human Eye to the Light Flicker / Peretto, L; Rovati, Luigi; Salvatori, G; Tinarelli, R; Emanuel, A. E.. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 56:4(2007), pp. 1384-1390. [10.1109/TIM.2007.899855]

A Measurement System for the Analysis of the Response of the Human Eye to the Light Flicker

ROVATI, Luigi;
2007

Abstract

The response of the human eye to flicker depends on the type of lamp used. Standard flickermeters measure the voltage across the lamp and assumes a 60-W incandescent lamp as a light source. When a different lamp is the light flicker source, standard flickermeters give erroneous results. This paper presents a dynamic model of the eye-brain response to flicker. The model is based on the analysis of the light emitted by the lamp. A suitable measurement system has been developed, and three different kinds of lamps have been considered. Experimental results show how the emitted light spectra and the human eye response to different colors combined to determine the level of annoyance. The uncertainty affecting such results, which arises from the hardware of the developed system, has been also estimated.
2007
56
4
1384
1390
A Measurement System for the Analysis of the Response of the Human Eye to the Light Flicker / Peretto, L; Rovati, Luigi; Salvatori, G; Tinarelli, R; Emanuel, A. E.. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 56:4(2007), pp. 1384-1390. [10.1109/TIM.2007.899855]
Peretto, L; Rovati, Luigi; Salvatori, G; Tinarelli, R; Emanuel, A. E.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/585647
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 24
social impact