The feasibility of non-invasive analysis of brain activities was studied in the attempt to overcome the major limitation of actual in vivo methodologies, i.e. invasiveness. Optic fibre probes were used as the optical head of a novel, highly sensitive near-infrared continuous wave spectroscopy (CW-NIR) instrument. This prototype was designed for non-invasive analysis of the two main forms of haemoglobin: oxy-haemoglobin (HbO2) and deoxy-haemoglobin (Hb), chromophores present in biological tissues. It was tested in peripheral tissue (human gastrocnemius muscle) and then reset to perform the measurement on rat brain. In animal studies, the optical head was firmly placed using stereotaxic apparatus upon the sagittal line of the head of anaesthetized adult rats, without any surgery. Then pharmacological treatments with saline (300 µl s.c.) amphetamine (2 mg kg−1) or nicotine (0.4 mg kg−1) were performed. Within 10–20 min amphetamine substantially increased HbO2 and reduced Hb control levels. Nicotine produced a rapid initial increase followed by a decrease in HbO2. In contrast to amphetamine, nicotine treatment also reduced Hb and blood volume. These results support the capacity of our CW-NIR prototype to measure non-invasively HbO2 and Hb levels in the rat brain, that are markers of the degree of tissue oxygenation, thus providing an index of blood levels and therefore of brain metabolism.

Near-infrared oxymeter biosensor prototype for non-invasive in vivo analysis of rat brain oxygenation: effects of drugs of abuse / Crespi, F; Donini, M; Bandera, A; Congestri, F; Formenti, F; Sonntag, V; Heidbreder, C; Rovati, Luigi. - In: JOURNAL OF OPTICS. A, PURE AND APPLIED OPTICS. - ISSN 1464-4258. - STAMPA. - 8:(2006), pp. 528-534. [10.1088/1464-4258/8/7/S35]

Near-infrared oxymeter biosensor prototype for non-invasive in vivo analysis of rat brain oxygenation: effects of drugs of abuse

ROVATI, Luigi
2006

Abstract

The feasibility of non-invasive analysis of brain activities was studied in the attempt to overcome the major limitation of actual in vivo methodologies, i.e. invasiveness. Optic fibre probes were used as the optical head of a novel, highly sensitive near-infrared continuous wave spectroscopy (CW-NIR) instrument. This prototype was designed for non-invasive analysis of the two main forms of haemoglobin: oxy-haemoglobin (HbO2) and deoxy-haemoglobin (Hb), chromophores present in biological tissues. It was tested in peripheral tissue (human gastrocnemius muscle) and then reset to perform the measurement on rat brain. In animal studies, the optical head was firmly placed using stereotaxic apparatus upon the sagittal line of the head of anaesthetized adult rats, without any surgery. Then pharmacological treatments with saline (300 µl s.c.) amphetamine (2 mg kg−1) or nicotine (0.4 mg kg−1) were performed. Within 10–20 min amphetamine substantially increased HbO2 and reduced Hb control levels. Nicotine produced a rapid initial increase followed by a decrease in HbO2. In contrast to amphetamine, nicotine treatment also reduced Hb and blood volume. These results support the capacity of our CW-NIR prototype to measure non-invasively HbO2 and Hb levels in the rat brain, that are markers of the degree of tissue oxygenation, thus providing an index of blood levels and therefore of brain metabolism.
2006
8
528
534
Near-infrared oxymeter biosensor prototype for non-invasive in vivo analysis of rat brain oxygenation: effects of drugs of abuse / Crespi, F; Donini, M; Bandera, A; Congestri, F; Formenti, F; Sonntag, V; Heidbreder, C; Rovati, Luigi. - In: JOURNAL OF OPTICS. A, PURE AND APPLIED OPTICS. - ISSN 1464-4258. - STAMPA. - 8:(2006), pp. 528-534. [10.1088/1464-4258/8/7/S35]
Crespi, F; Donini, M; Bandera, A; Congestri, F; Formenti, F; Sonntag, V; Heidbreder, C; Rovati, Luigi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/585643
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact