Rotating polarizer and rotating retarder plate polarimeters are widely used in high-resolution polarimetry, for example in remote sensing, fiber optic measurements and biomedics; as a consequence the analysis of the performances of these devices is very important from the instrumental point of view. To compare the two methods, we developed a synchronous polarimeter based on a mechanically rotating stage, where a rotating Glan-Thompson linear polarizer or a wave retarder can be easily mounted. A specific design allows to acquire synchronously the intensity signals digitally process the data to extract the polarization Stokes parameters. We investigate the two cases along with their impact on measurement techniques. Performance curves are shown for various polarization input parameters and light levels. Specifically, we address issues concerning the accuracy and the systematic and statistical measuring errors. Moreover, computer simulations and measurement results are presented and discussed.

Rotating polarizer and rotating retarder plate polarimeters: comparison of performances / Pelizzari, S.; Rovati, Luigi; De Angelis, C.. - STAMPA. - 4285:(2001), pp. 235-243. ( Conference on Testing, Reliability, and Applications of Optoelectronic Devices SAN JOSE, CA JAN 24-26, 2001) [10.1117/12.426894].

Rotating polarizer and rotating retarder plate polarimeters: comparison of performances

ROVATI, Luigi;
2001

Abstract

Rotating polarizer and rotating retarder plate polarimeters are widely used in high-resolution polarimetry, for example in remote sensing, fiber optic measurements and biomedics; as a consequence the analysis of the performances of these devices is very important from the instrumental point of view. To compare the two methods, we developed a synchronous polarimeter based on a mechanically rotating stage, where a rotating Glan-Thompson linear polarizer or a wave retarder can be easily mounted. A specific design allows to acquire synchronously the intensity signals digitally process the data to extract the polarization Stokes parameters. We investigate the two cases along with their impact on measurement techniques. Performance curves are shown for various polarization input parameters and light levels. Specifically, we address issues concerning the accuracy and the systematic and statistical measuring errors. Moreover, computer simulations and measurement results are presented and discussed.
2001
Inglese
Conference on Testing, Reliability, and Applications of Optoelectronic Devices
SAN JOSE, CA
JAN 24-26, 2001
TESTING RELIABILITY AND APPLICATIONS OF OPTOELECTRONIC DEVICES
4285
235
243
SPIE-INT SOC OPTICAL ENGINEERING
STATI UNITI D'AMERICA
1000 20TH ST, PO BOX 10, BELLINGHAM, WA 98227-0010 USA
Polarimeter; Stokes parameters; linear polarizer; quarter wave retarder
Pelizzari, S.; Rovati, Luigi; De Angelis, C.
Atti di CONVEGNO::Relazione in Atti di Convegno
273
3
Rotating polarizer and rotating retarder plate polarimeters: comparison of performances / Pelizzari, S.; Rovati, Luigi; De Angelis, C.. - STAMPA. - 4285:(2001), pp. 235-243. ( Conference on Testing, Reliability, and Applications of Optoelectronic Devices SAN JOSE, CA JAN 24-26, 2001) [10.1117/12.426894].
none
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/466682
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact