Over the past two decades, great efforts have been made in ophthalmology to use optical techniques based on dynamic light scattering and tissue natural fluorescence for early (at molecular level) diagnosis of ocular pathologies. In our previous studies, the relationship between the corneal AF and DLS decay widths of ocular tissues were established by performing measurements on diabetes mellitus patients. In those studies, corneal AF mean intensities were significantly correlated with DLS decay width measurements for each diabetic retinopathy grade in the vitreous and in the cornea. This suggested that the quality of the diagnosis could be significantly improved by properly combining these two powerful techniques into a single instrument. Our approach is based on modifying a commercial scanning ocular fluorometer (Fluorotron Master, Ocumetrics Inc., CA, USA) to include both techniques in the same scanning unit. This configuration provides both DLS and AF real time measurements from the same ocular volume: they can be located in each section of the optical axis of the eye from the cornea to the retina. In this paper, the optical setup of the new system is described and preliminary in-vitro and in-vivo measurements are presented.

Integrated instrument for dynamic light scattering and natural fluorescence measurements / Rovati, Luigi; Pollonini, L.; Ansari, R. R.. - STAMPA. - 4245:(2001), pp. 192-198. (Intervento presentato al convegno 11th Conference on Ophthalmic Technologies XI tenutosi a SAN JOSE, CA nel JAN 20-21, 2001) [10.1117/12.429271].

Integrated instrument for dynamic light scattering and natural fluorescence measurements

ROVATI, Luigi;
2001

Abstract

Over the past two decades, great efforts have been made in ophthalmology to use optical techniques based on dynamic light scattering and tissue natural fluorescence for early (at molecular level) diagnosis of ocular pathologies. In our previous studies, the relationship between the corneal AF and DLS decay widths of ocular tissues were established by performing measurements on diabetes mellitus patients. In those studies, corneal AF mean intensities were significantly correlated with DLS decay width measurements for each diabetic retinopathy grade in the vitreous and in the cornea. This suggested that the quality of the diagnosis could be significantly improved by properly combining these two powerful techniques into a single instrument. Our approach is based on modifying a commercial scanning ocular fluorometer (Fluorotron Master, Ocumetrics Inc., CA, USA) to include both techniques in the same scanning unit. This configuration provides both DLS and AF real time measurements from the same ocular volume: they can be located in each section of the optical axis of the eye from the cornea to the retina. In this paper, the optical setup of the new system is described and preliminary in-vitro and in-vivo measurements are presented.
2001
11th Conference on Ophthalmic Technologies XI
SAN JOSE, CA
JAN 20-21, 2001
4245
192
198
Rovati, Luigi; Pollonini, L.; Ansari, R. R.
Integrated instrument for dynamic light scattering and natural fluorescence measurements / Rovati, Luigi; Pollonini, L.; Ansari, R. R.. - STAMPA. - 4245:(2001), pp. 192-198. (Intervento presentato al convegno 11th Conference on Ophthalmic Technologies XI tenutosi a SAN JOSE, CA nel JAN 20-21, 2001) [10.1117/12.429271].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/466681
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact