In this paper the problem of anaesthetic gases dilution in operating theatres has been examined, by experiences carried out in a full scale testing room. The performance of two different HVAC plants have been compared, one of them working in static conditions at 20 external air changes per hour, whereas the other has been dynamically driven by an automatic control system between 10 and 20 external air changes per hour. In the latter case, the flow control operate as a function of the concentration level of tracer gas, simulating a pollutant, sampled in real time by a suitable monitoring system. The results demonstrate that a dynamic HVAC system can guarantee good environmental conditions and satisfactory comfort, as well as remarkable energy savings.

Energy Savings and dynamical Control of HVAC Systems in operating Theatre: an Experimental Approach / Borella, A.; Dumas, Antonio; Mazzacane, S.. - STAMPA. - 1:(1998), pp. 213-218. (Intervento presentato al convegno International conference on air distribution in rooms No6 tenutosi a Stockholm , SUEDE nel June 14-17,STOCKHOLM).

Energy Savings and dynamical Control of HVAC Systems in operating Theatre: an Experimental Approach

DUMAS, Antonio;
1998

Abstract

In this paper the problem of anaesthetic gases dilution in operating theatres has been examined, by experiences carried out in a full scale testing room. The performance of two different HVAC plants have been compared, one of them working in static conditions at 20 external air changes per hour, whereas the other has been dynamically driven by an automatic control system between 10 and 20 external air changes per hour. In the latter case, the flow control operate as a function of the concentration level of tracer gas, simulating a pollutant, sampled in real time by a suitable monitoring system. The results demonstrate that a dynamic HVAC system can guarantee good environmental conditions and satisfactory comfort, as well as remarkable energy savings.
1998
International conference on air distribution in rooms No6
Stockholm , SUEDE
June 14-17,STOCKHOLM
1
213
218
Borella, A.; Dumas, Antonio; Mazzacane, S.
Energy Savings and dynamical Control of HVAC Systems in operating Theatre: an Experimental Approach / Borella, A.; Dumas, Antonio; Mazzacane, S.. - STAMPA. - 1:(1998), pp. 213-218. (Intervento presentato al convegno International conference on air distribution in rooms No6 tenutosi a Stockholm , SUEDE nel June 14-17,STOCKHOLM).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/464731
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact