The effect of varying initial liquid-solid contact angle on theevaporation of single droplets of water deposited on a stainless steel surface is studied using both experiments and numerical modeling. Contact angle is controlled in experiments by adding varying amounts (100 and 1000ppm) of a surfactant to water. The evolution of contact angle and liquid-solid contact diameter is measured from a video record of droplet evaporation. The computer model is validated by comparison with the experimental results. Reducing the contact angle increases the contact area between the droplet and solid surface, and also reduces droplet thickness, enhancing heat conduction through thedrop,!et. Both effects increase the droplet evaporation rate. Decreasing the initial contact angle from 90 to 20 ° reduces droplet evaporation time by approximately 50%. The computer model is used to calculate surface temperature and heat flux variation during droplet evaporation: adding 1000ppm of surfactant to the droplet is shown to enhance surfacecooling by up to 110%.
Effect of Liquid-Solid Contact Angle on Droplet Evaporation / S., Chandra; M., di Marzo; Y. M., Qiao; Tartarini, Paolo. - In: FIRE SAFETY JOURNAL. - ISSN 0379-7112. - STAMPA. - 27:(1996), pp. 141-158.
Effect of Liquid-Solid Contact Angle on Droplet Evaporation
TARTARINI, Paolo
1996
Abstract
The effect of varying initial liquid-solid contact angle on theevaporation of single droplets of water deposited on a stainless steel surface is studied using both experiments and numerical modeling. Contact angle is controlled in experiments by adding varying amounts (100 and 1000ppm) of a surfactant to water. The evolution of contact angle and liquid-solid contact diameter is measured from a video record of droplet evaporation. The computer model is validated by comparison with the experimental results. Reducing the contact angle increases the contact area between the droplet and solid surface, and also reduces droplet thickness, enhancing heat conduction through thedrop,!et. Both effects increase the droplet evaporation rate. Decreasing the initial contact angle from 90 to 20 ° reduces droplet evaporation time by approximately 50%. The computer model is used to calculate surface temperature and heat flux variation during droplet evaporation: adding 1000ppm of surfactant to the droplet is shown to enhance surfacecooling by up to 110%.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris