Activation of coagulation during hemodialysis (HD) is a relevant clinical problem, especially when patients at risk of bleeding are treated. However, little is known about the relative contribution of the various components of the circuit to the thrombotic process. Thus, an experimental model was developed that is aimed at evaluating biochemical markers of coagulation activation at different times and sites throughout the HD circuit. A HD blood-tubing set with integrated arterial and venous chambers (cartridge-line set) was used, which was added with the following sampling points: at the beginning of the arterial line (P1), before the blood pump (P2), after the blood pump (P3), and at the end of the venous line (P4). A bypass system allowed us to circulate the blood only into the blood lines for the first 20 min of the extracorporeal circulation. The extracorporeal circuit was rinsed with 1.7 L of heparinized saline (2,500 IU/L) that was completely discarded before patient connection. A continuous administration of unfractionated heparin (500-800 IU/h) without a starting bolus was adopted as a low heparin extracorporeal treatment. Samples were collected before the start of the extracorporeal circulation from the fistula needle (T0P0), after 5 (T1), 10 (T2), and 20 min (T3) from P1, P2, P3, and P4. After 20 min, the blood was returned to the patient using only saline and HD was then started, circulating the blood through the dialyzer. Further samples were obtained from P1 and P4 after 5 (T4) and 210 min (T5). Plasma levels of coagulation activation markers-thrombin-antithrombin complex (TAT) and prothrombin fragment 1 + 2 (F1 + 2)-were evaluated in all the samples in 12 stable HD patients. In each patient, the activated partial thromboplastin time (APTT) was measured at T0P0 and T1-T5 from P1. No significant changes were found at any time as far as F1 + 2 is concerned. However, TAT levels increased over time only after the start of HD, suggesting that the latter test could be more useful in order to detect coagulation activation during HD. The same experiments performed with nonheparin-primed extracorporeal circuit showed similar results. The blood lines used did not significantly activate coagulation during the first 20 min, whereas only 5 min of blood circulation throughout the whole circuit increased TAT values, which still remained lower than previous reports, even after 210 min of treatment.
Activation of coagulation during hemodialysis: effect of blood lines alone and whole extracorporeal circuit / Lucchi, L; Ligabue, Giulia; Marietta, M; Delnevo, A; Malagoli, M; Perrone, S; Stipo, L; Grandi, F; Albertazzi, Alberto. - In: ARTIFICIAL ORGANS. - ISSN 0160-564X. - STAMPA. - 30:2(2006), pp. 106-110. [10.1111/j.1525-1594.2006.00188.x]
Activation of coagulation during hemodialysis: effect of blood lines alone and whole extracorporeal circuit.
LIGABUE, Giulia;ALBERTAZZI, Alberto
2006
Abstract
Activation of coagulation during hemodialysis (HD) is a relevant clinical problem, especially when patients at risk of bleeding are treated. However, little is known about the relative contribution of the various components of the circuit to the thrombotic process. Thus, an experimental model was developed that is aimed at evaluating biochemical markers of coagulation activation at different times and sites throughout the HD circuit. A HD blood-tubing set with integrated arterial and venous chambers (cartridge-line set) was used, which was added with the following sampling points: at the beginning of the arterial line (P1), before the blood pump (P2), after the blood pump (P3), and at the end of the venous line (P4). A bypass system allowed us to circulate the blood only into the blood lines for the first 20 min of the extracorporeal circulation. The extracorporeal circuit was rinsed with 1.7 L of heparinized saline (2,500 IU/L) that was completely discarded before patient connection. A continuous administration of unfractionated heparin (500-800 IU/h) without a starting bolus was adopted as a low heparin extracorporeal treatment. Samples were collected before the start of the extracorporeal circulation from the fistula needle (T0P0), after 5 (T1), 10 (T2), and 20 min (T3) from P1, P2, P3, and P4. After 20 min, the blood was returned to the patient using only saline and HD was then started, circulating the blood through the dialyzer. Further samples were obtained from P1 and P4 after 5 (T4) and 210 min (T5). Plasma levels of coagulation activation markers-thrombin-antithrombin complex (TAT) and prothrombin fragment 1 + 2 (F1 + 2)-were evaluated in all the samples in 12 stable HD patients. In each patient, the activated partial thromboplastin time (APTT) was measured at T0P0 and T1-T5 from P1. No significant changes were found at any time as far as F1 + 2 is concerned. However, TAT levels increased over time only after the start of HD, suggesting that the latter test could be more useful in order to detect coagulation activation during HD. The same experiments performed with nonheparin-primed extracorporeal circuit showed similar results. The blood lines used did not significantly activate coagulation during the first 20 min, whereas only 5 min of blood circulation throughout the whole circuit increased TAT values, which still remained lower than previous reports, even after 210 min of treatment.Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris