The article describes an instrument designed to perform in vivo near-infrared spectroscopic measurements on human tissues. The system integrates five continuous-wave laser diode sources emitting in the near-infrared spectral region and a low-noise detection system based on an avalanche photodiode. The optical probe is based on a compact, reliable, and low-cost fiber based system with four quantitative measuring points. The excellent sensitivity of the instrument allows one to perform quantitative assessments of the hemoglobin concentration exploiting precise absorption measurements close to the absorption peak of the water: 975 nm. Moreover, a good signal to noise ratio is obtained also at a high acquisition rate, allowing us to follow rapid changes in oxidative metabolism. The system bandwidth is selectable within the range 2.3-27 Hz, i.e., 20 channels (five chromatic and four spatial channels) can be acquired 27 times for each measuring second, whereas the system amplification can be set to measure optical density ranging from 3.5 to 8.5. A prototype version of the instrument has been realized and characterized.

Design and performance of a wide-bandwidth and sensitive instrument for near-infrared spectroscopic measurements on human tissue / Rovati, Luigi; Bandera, A; Donini, M; Salvatori, G; Pollonini, L.. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - STAMPA. - 75:12(2004), pp. 5315-5325. [10.1063/1.1818588]

Design and performance of a wide-bandwidth and sensitive instrument for near-infrared spectroscopic measurements on human tissue

ROVATI, Luigi;
2004

Abstract

The article describes an instrument designed to perform in vivo near-infrared spectroscopic measurements on human tissues. The system integrates five continuous-wave laser diode sources emitting in the near-infrared spectral region and a low-noise detection system based on an avalanche photodiode. The optical probe is based on a compact, reliable, and low-cost fiber based system with four quantitative measuring points. The excellent sensitivity of the instrument allows one to perform quantitative assessments of the hemoglobin concentration exploiting precise absorption measurements close to the absorption peak of the water: 975 nm. Moreover, a good signal to noise ratio is obtained also at a high acquisition rate, allowing us to follow rapid changes in oxidative metabolism. The system bandwidth is selectable within the range 2.3-27 Hz, i.e., 20 channels (five chromatic and four spatial channels) can be acquired 27 times for each measuring second, whereas the system amplification can be set to measure optical density ranging from 3.5 to 8.5. A prototype version of the instrument has been realized and characterized.
2004
75
12
5315
5325
Design and performance of a wide-bandwidth and sensitive instrument for near-infrared spectroscopic measurements on human tissue / Rovati, Luigi; Bandera, A; Donini, M; Salvatori, G; Pollonini, L.. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - STAMPA. - 75:12(2004), pp. 5315-5325. [10.1063/1.1818588]
Rovati, Luigi; Bandera, A; Donini, M; Salvatori, G; Pollonini, L.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/4002
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact