The efficiency of a hemodialyzer is largely dependent on ifs ability to facilitate diffusion, since this is the main mechanism by which small solutes are removed. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. The objective of the paper was to study the impact of different dialysate compartment designs on dialysate flow distribution and urea clearances. Eighteen hollow fiber 1.3 m(2) hemodialyzers were studied, 6 each of 3 designs: Type A - standard fiber bundle (PAN 65DX Asahi Medical, Tokyo, Japan), Type B - spacing filaments external to the fibers (PAN 65SF Asahi Medical, Tokyo, Japan), Type C - fibers waved to give Moire structure (FB130 Nissho-Nipro, Osaka, Japan). In vitro studies: 3 dialyzers of each type were studied following dye injection into the dialysate compartment. Dynamic sequential imaging of longitudinal sections of the dialyzer were undertaken, using a new generation helical CT scanner (X-Press/HS1 Toshiba Corporation, Tokyo, Japan). In vivo studies: 3 dialyzers of each type were studied, in randomized sequence, in 3 different patients under standardized dialysis conditions. Blood- and dialysate-side urea clearances were measured at 30 and 150 minutes of treatment. Macroscopic and densitometrical analysis revealed that flow distribution was most homogeneous in the dialyzer with Moire structure (Type C) and least homogeneous in the standard dialyzer (Type A). Space yarns (Type B) gave an intermediate dialysate flow distribution. Significantly increased urea clearances (p<0.001) were seen with Types B and C, compared to the standard dialyzer. Type C (Moire) had the highest clearances although these were not significantly greater than Type B (space yarns). In conclusion, more homogeneous dialysate flow distribution and improved small solute clearances can be achieved by use of spacing yarns or waved (Moire structure) patterns of fiber packing in the dialyzer. These effects are achieved probably as a result of reduced dialysate channeling resulting in a lower degree of mismatch between blood and dialysate flows. The new radiological technique using the helical CT scanner allows detailed flow distribution analysis and has the potential for testing future modifications to dialyzer design.

Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations / C., Ronco; A., Brendolan; C., Crepaldi; M., Rodighiero; P., Everard; M., Ballestri; Cappelli, Gianni; M., Spittle; G., La Greca. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - STAMPA. - 23:9(2000), pp. 601-609. [10.1177/039139880002300902]

Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations

CAPPELLI, Gianni;
2000

Abstract

The efficiency of a hemodialyzer is largely dependent on ifs ability to facilitate diffusion, since this is the main mechanism by which small solutes are removed. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. The objective of the paper was to study the impact of different dialysate compartment designs on dialysate flow distribution and urea clearances. Eighteen hollow fiber 1.3 m(2) hemodialyzers were studied, 6 each of 3 designs: Type A - standard fiber bundle (PAN 65DX Asahi Medical, Tokyo, Japan), Type B - spacing filaments external to the fibers (PAN 65SF Asahi Medical, Tokyo, Japan), Type C - fibers waved to give Moire structure (FB130 Nissho-Nipro, Osaka, Japan). In vitro studies: 3 dialyzers of each type were studied following dye injection into the dialysate compartment. Dynamic sequential imaging of longitudinal sections of the dialyzer were undertaken, using a new generation helical CT scanner (X-Press/HS1 Toshiba Corporation, Tokyo, Japan). In vivo studies: 3 dialyzers of each type were studied, in randomized sequence, in 3 different patients under standardized dialysis conditions. Blood- and dialysate-side urea clearances were measured at 30 and 150 minutes of treatment. Macroscopic and densitometrical analysis revealed that flow distribution was most homogeneous in the dialyzer with Moire structure (Type C) and least homogeneous in the standard dialyzer (Type A). Space yarns (Type B) gave an intermediate dialysate flow distribution. Significantly increased urea clearances (p<0.001) were seen with Types B and C, compared to the standard dialyzer. Type C (Moire) had the highest clearances although these were not significantly greater than Type B (space yarns). In conclusion, more homogeneous dialysate flow distribution and improved small solute clearances can be achieved by use of spacing yarns or waved (Moire structure) patterns of fiber packing in the dialyzer. These effects are achieved probably as a result of reduced dialysate channeling resulting in a lower degree of mismatch between blood and dialysate flows. The new radiological technique using the helical CT scanner allows detailed flow distribution analysis and has the potential for testing future modifications to dialyzer design.
2000
23
9
601
609
Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations / C., Ronco; A., Brendolan; C., Crepaldi; M., Rodighiero; P., Everard; M., Ballestri; Cappelli, Gianni; M., Spittle; G., La Greca. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - STAMPA. - 23:9(2000), pp. 601-609. [10.1177/039139880002300902]
C., Ronco; A., Brendolan; C., Crepaldi; M., Rodighiero; P., Everard; M., Ballestri; Cappelli, Gianni; M., Spittle; G., La Greca
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/305584
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 32
social impact