Conventional-size electrodes and microelectrodes coated by electrogenerated poly[4,4'-bis(butylsulfanyl)-2,2'-bithiophene] have been tested with respect to the electrocatalytic oxidation of a particularly interesting analyte, i.e., ascorbic acid, in different concentrations of phosphate buffer, aqueous solution. Linear sweep and cyclic voltammetry have been used and the quantities related to the analyte concentration were the peak current and the diffusion (t(-1/2)) deconvoluted peak current in the case of conventional-size and of microelectrode, respectively. Fairly good linear correlation could be found; a particularly wide linearity range was obtained by working with the microelectrode. It showed to give good results also at a very low (10(-4) M) phosphate buffer-supporting electrolyte concentration. The actual interference on the analysis of compounds often coupled with ascorbic acid in natural or pharmaceutical products has been studied.
Polythiophene derivative conducting polymer modified electrodes and microelectrodes for determination of ascorbic acid. Effect of possible interferents / S., Lupu; Mucci, Adele; Pigani, Laura; Seeber, Renato; Zanardi, Chiara. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 14:7-8(2002), pp. 519-525. [10.1002/1521-4109(200204)14:7/8<519::AID-ELAN519>3.0.CO;2-G]
Polythiophene derivative conducting polymer modified electrodes and microelectrodes for determination of ascorbic acid. Effect of possible interferents
MUCCI, Adele;PIGANI, Laura;SEEBER, Renato;ZANARDI, Chiara
2002
Abstract
Conventional-size electrodes and microelectrodes coated by electrogenerated poly[4,4'-bis(butylsulfanyl)-2,2'-bithiophene] have been tested with respect to the electrocatalytic oxidation of a particularly interesting analyte, i.e., ascorbic acid, in different concentrations of phosphate buffer, aqueous solution. Linear sweep and cyclic voltammetry have been used and the quantities related to the analyte concentration were the peak current and the diffusion (t(-1/2)) deconvoluted peak current in the case of conventional-size and of microelectrode, respectively. Fairly good linear correlation could be found; a particularly wide linearity range was obtained by working with the microelectrode. It showed to give good results also at a very low (10(-4) M) phosphate buffer-supporting electrolyte concentration. The actual interference on the analysis of compounds often coupled with ascorbic acid in natural or pharmaceutical products has been studied.File | Dimensione | Formato | |
---|---|---|---|
Lupu_et_al-2002-Electroanalysis.pdf
Accesso riservato
Tipologia:
VOR - Versione pubblicata dall'editore
Dimensione
740.38 kB
Formato
Adobe PDF
|
740.38 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris